Skip Navigation



Radiation Protection Dosimetry Advance Access published online on March 28, 2008

Radiation Protection Dosimetry, doi:10.1093/rpd/ncn090
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
130/4/518    most recent
ncn090v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Datz, H.
Right arrow Articles by Margaliot, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Datz, H.
Right arrow Articles by Margaliot, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2008. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

THE ADDITIONAL DOSE TO RADIOSENSITIVE ORGANS CAUSED BY USING UNDER-COLLIMATED X-RAY BEAMS IN NEONATAL INTENSIVE CARE RADIOGRAPHY

Hanan Datz1,2,*, Avi Ben-Shlomo1, David Bader3, Siegal Sadetzki4,5, Ada Juster-Reicher6, Kyla Marks7, Tatiana Smolkin8, Samuel Zangen9 and Menachem Margaliot1

1 Soreq Nuclear Research Center, Radiation Safety Division, Yavne, Israel
2 Department of Biomedical Engineering at Ben-Gurion University of the Negev, Beer-Sheva, Israel
3 Bnai-Zion Medical Center, Department of Neonatology, Haifa, Israel
4 Cancer & Radiation Epidemiology Unit, Gertner Institute, Chaim Sheba Medical Center, Israel
5 Sackler School of Medicine, Tel Aviv University, Israel
6 Kaplan Medical Center, Department of Neonatology, Rehovot, Israel
7 Soroka Medical Center, Department of Neonatology, Beer-Sheva, Israel
8 Rambam Medical Center, Department of Neonatology, Haifa, Israel
9 Barzilay Medical Center, Department of Neonatology, Ashkelon, Israel

* Corresponding author: datz{at}soreq.gov.il

Received February 7, 2007, amended February 18, 2008, accepted February 26, 2008

Radiographic technique and exposure parameters were recorded in five Israeli Neonatal Intensive Care Units for chest, abdomen and both chest and abdomen X-ray examinations. Equivalent dose and effective dose values were calculated according to actual examination field size borders and proper technique field size recommendations using PCXMC, a PC-based Monte Carlo program. Exposure of larger than required body areas resulted in an increase of the organ doses by factors of up to 162 (testes), 162 (thyroid) and 8 (thyroid) for chest, abdomen and both chest and abdomen examinations, respectively. These exposures increased the average effective dose by factors of 2.0, 1.9 and 1.3 for the chest, abdomen and both chest and abdomen examinations, respectively. Differences in exposure parameters were found between the different neonatal intensive care units—tube voltage, current–time product and focal to skin distance differences up to 13, 44 and 22%, respectively. Reduction of at least 50% of neonate exposure is feasible and can be implemented using existing methodology without any additional costs.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.