Skip Navigation



Radiation Protection Dosimetry Advance Access published online on February 18, 2008

Radiation Protection Dosimetry, doi:10.1093/rpd/ncn028
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
129/1-3/50    most recent
ncn028v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Bleeser, F.
Right arrow Articles by Bosmans, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bleeser, F.
Right arrow Articles by Bosmans, H.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2008. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

DIAGNOSTIC REFERENCE LEVELS IN ANGIOGRAPHY AND INTERVENTIONAL RADIOLOGY: A BELGIAN MULTI-CENTRE STUDY

F. Bleeser1, M.-T. Hoornaert1,*, K. Smans2,3, L. Struelens3, N. Buls4, D. Berus4, P. Clerinx4, L. Hambach5, F. Malchair5 and H. Bosmans2

1 CH Jolimont-Lobbes, 159 rue Ferrer, 7100 Haine Saint-Paul, Belgium
2 UZ Gasthuisberg, Herestraat, 3000 Leuven, Belgium
3 SCK-CEN, Mol, Belgium
4 AZ VUB, Laarbeeklaan, 1090 Brussels, Belgium
5 Centre Hospitalier Universitaire, Sart Tilman, 4000 Liège, Belgium

* Corresponding author: mt.hoornaert{at}skynet.be

The purpose of this study was to determine diagnostic reference levels (DRLs) for common angiographic and interventional procedures in Belgium. Dose Area Product (DAP) measurements were performed on 21 systems, (13 angiography and 4 vascular surgery centres). Type of procedure, total DAP, patient weight and height were collected on a daily basis during 1 y. The 75th percentile of the distribution of DAP values was defined as DRL. Preliminary DRLs were calculated for the three most frequent procedures for the whole population, for a weight class of patients (65–80 kg) and normalised to the standard size patient. Among them, the DRL for angiography of the lower limbs (30% of the procedures) from the whole population was 74.6 and 63.2 Gycm2 for the size corrected. The mean DAP values of each room was then compared to these DRLs.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.