Radiation Protection Dosimetry Advance Access published online on February 18, 2008
Radiation Protection Dosimetry, doi:10.1093/rpd/ncn017
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
OCCUPATONAL RADIATION DOSES IN INTERVENTIONAL RADIOLOGY: SIMULATIONS
STUK—Radiation and Nuclear Safety Authority, PO Box 14, FI-00881 Helsinki, Finland
* Corresponding author: teemu.siiskonen{at}stuk.fi
In interventional radiology, occupational radiation doses can be high. Therefore, many authors have established conversion coefficients from the dose–area product data or from the personal dosemeter reading to the effective dose of the radiologist. These conversion coefficients are studied also in this work, with an emphasis on sensitivity of the results to changes in exposure conditions. Comparison to earlier works indicates that, for the exposure conditions examined in this work, all previous models discussed in this work overestimate the effective dose of the radiologist when a lead apron and a thyroid shield are used. Without the thyroid shield, underestimation may occur with some models.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
I. Prlic, M. Suric Mihic, and Z. Vucic ACTIVE ELECTRONIC PERSONAL DOSEMETER IN INTERVENTIONAL RADIOLOGY Radiat Prot Dosimetry, December 5, 2008; (2008) ncn294v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Zuguchi, K. Chida, M. Taura, Y. Inaba, A. Ebata, and S. Yamada USEFULNESS OF NON-LEAD APRONS IN RADIATION PROTECTION FOR PHYSICIANS PERFORMING INTERVENTIONAL PROCEDURES Radiat Prot Dosimetry, September 17, 2008; (2008) ncn244v1. [Abstract] [Full Text] [PDF] |
||||