Skip Navigation



Radiation Protection Dosimetry Advance Access published online on February 18, 2007

Radiation Protection Dosimetry, doi:10.1093/rpd/ncm143
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
124/2/181    most recent
ncm143v2
ncm143v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Looe, H. K.
Right arrow Articles by Poppe, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Looe, H. K.
Right arrow Articles by Poppe, B.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2007. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org
Received September 26, 2006
Revised November 24, 2006
Accepted December 22, 2006

SCIENTIFIC AND TECHNICAL PAPER

DOSE-AREA PRODUCT MEASUREMENTS AND DETERMINATION OF CONVERSION COEFFICIENTS FOR THE ESTIMATION OF EFFECTIVE DOSE IN DENTAL LATERAL CEPHALOMETRIC RADIOLOGY

H. K. Looe 1 *, F. Eenboom 1, N. Chofor 1, A. Pfaffenberger 1, M. Sering 2, A. Rühmann 3, A. Poplawski 3, K. Willborn 3, and B. Poppe 1

1 Medical Radiation Physics Working Group, Carl von Ossietzky University Oldenburg, 26111 Oldenburg, Germany; Clinic of Radiotherapy and Oncology, Pius-Hospital, Georgstrasse 12, 26121 Oldenburg, Germany
2 Öko-Institut e.V., Darmstadt Office, Nuclear Engineering & Plant Safety Division, Rheinstrasse 95, 64295 Darmstadt, Germany
3 Clinic of Radiotherapy and Oncology, Pius-Hospital, Georgstrasse 12, 26121 Oldenburg, Germany

* To whom correspondence should be addressed.
H. K. Looe, E-mail: hui.k.looe{at}uni-oldenburg.de


   Abstract

A study has been carried out to propose diagnostic reference levels (DRLs) for lateral cephalometric radiology in Germany based on the dose-area product (DAP). DRLs were proposed separately for child and adult exposure settings which are 26.4 and 32.6 mGy cm2, respectively. Organ absorbed doses from lateral cephalometric radiology were also measured using thermoluminescence detectors (TLDs) and an adult anthropomorphic phantom specially design for dosimetric study in dental radiology. Effective doses were then calculated using three different techniques where the salivary gland and brain tissue were given different weighting factors. Conversion coefficients for estimating effective dose from DAP value derived in this study range from 0.042 to 0.149 µSv/mGy cm2.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
H. K. Looe, F. Eenboom, N. Chofor, A. Pfaffenberger, M. Steinhoff, A. Ruhmann, A. Poplawski, K. Willborn, and B. Poppe
Conversion coefficients for the estimation of effective doses in intraoral and panoramic dental radiology from dose-area product values
Radiat Prot Dosimetry, September 1, 2008; 131(3): 365 - 373.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.