Skip Navigation



Radiation Protection Dosimetry Advance Access published online on December 14, 2006

Radiation Protection Dosimetry, doi:10.1093/rpd/ncl502
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
123/4/498    most recent
ncl502v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Acun, H.
Right arrow Articles by Karadeniz, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Acun, H.
Right arrow Articles by Karadeniz, A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org
Received June 21, 2006
Revised October 31, 2006
Accepted November 3, 2006

SCIENTIFIC AND TECHNICAL PAPER

DOSIMETRIC ANALYSIS OF THYROID DOSES FROM TOTAL CRANIAL IRRADIATION

H. Acun 1, G. Kemikler 1 *, and A. Karadeniz 2

1 Department of Medical Radiophysics, Oncology Institute, Istanbul University, Topkapi, 34390, Istanbul Turkey
2 Department of Radiation Oncology, Oncology Institute, Istanbul University, Topkapi, 34390, Istanbul, Turkey

* To whom correspondence should be addressed.
G. Kemikler, E-mail: gkemikler{at}superonline.com


   Abstract

The purpose was to estimate the radiation dose to the thyroid from total cranial irradiation with parallel opposed lateral fields of 1.25 MeV gamma rays of 60Co, to represent the current treatment modality, and with 6 MV photon beams derived from a linear accelerator. The mean thyroid doses were measured using thermoluminescence dosemeters in the Rando phantom with two cranial irradiation set-ups: (1) the lateral beams were angled by rotating the collimator to avoid irradiation of the lens and healthy tissues and (2) the lateral beams were not angled, and shielding blocks were used to protect the lens and healthy tissues. For a cranial dose of 18 Gy, thyroid doses for child patients for 60Co with the open and blocked fields were 0.27 and 0.32 Gy, respectively. With 6 MV, the thyroid dose was less than the doses for 60Co open and blocked cranial fields by 17 and 10%, respectively. Unblocked cranial fields and a high-energy photon beam should be preferred for cranial irradiation of children.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.