Skip Navigation



Radiation Protection Dosimetry Advance Access published online on September 20, 2006

Radiation Protection Dosimetry, doi:10.1093/rpd/ncl141
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
123/2/246    most recent
ncl141v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Seierstad, T.
Right arrow Articles by Wetteland, O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Seierstad, T.
Right arrow Articles by Wetteland, O.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Published by Oxford University Press (2006).
Received April 4, 2006
Revised June 13, 2006
Accepted August 18, 2006

SCIENTIFIC NOTE

DOSES TO NUCLEAR TECHNICIANS IN A DEDICATED PET/CT CENTRE UTILISING 18F FLUORODEOXYGLUCOSE (FDG)

T. Seierstad 1, E. Stranden 1 *, K. Bjering 2, M. Evensen 1, A. Holt 1, H. M. Michalsen 1, and O. Wetteland 1

1 Buskerud University College, Faculty of Health, Konggate 51, N-3019 Drammen, Norway
2 Department of Nuclear Medicine Rikshospitalet-Radiumhospitalet HF, Montebello, N-0310 Oslo, Norway

* To whom correspondence should be addressed.
E. Stranden, E-mail: erling.stranden{at}hibu.no


   Abstract

The first dedicated PET/CT centre in Norway was established at the Norwegian Radiumhospital in Oslo in 2005. Knowing that the introductions of PET-isotopes in nuclear medicine give increased occupational radiation dose to the technicians, a study was carried out in order to map the doses to staff members during different working operations and to see if any dose reducing measures were needed. The results of the study are in good agreement with other studies, and a technician dose of 20--25 nSv per injected MBq of 18F seems to be representative for such centres. For an average injected activity of 350 MBq per patient, the dose limit is reached after handling around 3000 patients annually. For an annual number of less than 500 patients at the centre and rotation of the staff, an annual individual dose for the technicians would realistically be less than 2--3 mSv. Even a major increase in the number of patients will not result in individual doses near the ICRP dose limit.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
U. S. Kristoffersen, H. Gutte, D. Skovgaard, P. A. Andersen, and A. Kjaer
RADIATION EXPOSURE FOR MEDICAL STAFF PERFORMING QUANTITATIVE CORONARY PERFUSION PET WITH 13N-AMMONIA
Radiat Prot Dosimetry, October 3, 2009; (2009) ncp202v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
E. Hippelainen, P. Nikkinen, T. Ihalainen, J. Uusi-Simola, and S. Savolainen
Personal radiation doses in PET/CT facility: measurements vs. calculations
Radiat Prot Dosimetry, December 1, 2008; 132(1): 57 - 63.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.