Skip Navigation



Radiation Protection Dosimetry Advance Access published online on April 5, 2006

Radiation Protection Dosimetry, doi:10.1093/rpd/ncl031
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
121/3/211    most recent
ncl031v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Porta, A.
Right arrow Articles by Caresana, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Porta, A.
Right arrow Articles by Caresana, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org
Received December 22, 2005
Revised February 6, 2006
Accepted February 19, 2006

TECHNICAL PAPER

COMPARATIVE PERFORMANCE TESTS OF THE FLUKA-RQMD SYSTEM AND EPAX 2 PREVISIONS VS. EXPERIMENTAL DATA

Alessandro Porta 1 *, Stefano Agosteo 2, Fabrizio Campi 1, and Marco Caresana 1

1 Dipartimento di Ingegneria Nucleare, Politecnico di Milano, via Ponzio 34/3, I-20133 Milano, Italy
2 Dipartimento di Ingegneria Nucleare, Politecnico di Milano, via Ponzio 34/3, I-20133 Milano, Italy; Istituto Nazionale di Fisica Nucleare, Sezione di Milano, via Celoria 16, 20133 Milano, Italy

* To whom correspondence should be addressed.
Alessandro Porta, E-mail: alessandro.porta{at}polimi.it


   Abstract

This work describes the tests performed on the RQMD module (available in the FLUKA code), to support nucleus-nucleus interactions above 100 MeV u-1. The RQMD-FLUKA system was used to simulate directly simple experimental set-ups to reproduce both secondary hadron production and residual nuclei distributions with ion beams ranging from 100 to 800 MeV u-1. Recent measurements of residual nuclei distributions due to interaction of light ion beams on high-purity targets were used as reference for testing the RQMD-FLUKA prediction capability. Together with FLUKA, the EPAX 2 code was considered as a further reference in fragmentation cross sections. EPAX shows a general tendency to underestimate the experimental fragmentation cross sections for the considered projectile-target combinations. EPAX underestimations are generally close to 40%, whereas FLUKA predictions are within 20% on the average.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.