Skip Navigation



Radiation Protection Dosimetry Advance Access published online on January 12, 2006

Radiation Protection Dosimetry, doi:10.1093/rpd/nck002
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
121/2/186    most recent
nck002v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Pillai, A.
Right arrow Articles by Jain, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pillai, A.
Right arrow Articles by Jain, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org
Received June 26, 2005
Revised December 4, 2005
Accepted December 20, 2005

SCIENTIFIC AND TECHNICAL PAPER

FLUROSCOPY IN PAEDIATRIC FRACTURES--SETTING A LOCAL DIAGNOSTIC REFERENCE LEVEL

Anand Pillai 1 *, Andrew McAuley 2, Kenneth McMurray 1, and Manav Jain 1

1 West of Scotland Region, Wishaw General Hospital, Wishaw, Lanarkshire, Scotland ML2 ODP
2 Lanarkshire ADAT, Strathclyde Hospital, Airbles Road, Motherwell, Scotland ML1 3BW

* To whom correspondence should be addressed.
Anand Pillai, E-mail: Aorthopod{at}aol.com


   Abstract

Background: The ionizing radiations (Medical Exposure) Regulation 2000 has made it mandatory to establish diagnostic reference levels (DRLs) for all typical radiological examinations. Objectives: We attempt to provide dose data for some common fluoroscopic procedures used in orthopaedic trauma that may be used as the basis for setting DRLs for paediatric patients. Materials and methods: The dose area product (DAP) in 865 paediatric trauma examinations was analysed. Median DAP values and screening times for each procedure type along with quartile values for each range are presented. Results: In the upper limb, elbow examinations had maximum exposure with a median DAP value of 1.21 cGy cm2. Median DAP values for forearm and wrist examinations were 0.708 and 0.538 cGy cm2, respectively. In lower limb, tibia and fibula examinations had a median DAP value of 3.23 cGy cm2 followed by ankle examinations with a median DAP of 3.10 cGy cm2. The rounded third quartile DAP value for each distribution can be used as a provisional DRL for the specific procedure type.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
G. J. Love, A. Pillai, and S. Gibson
Use of the mini C-arm for wrist fractures--establishing a diagnostic reference level
Radiat Prot Dosimetry, February 1, 2008; 128(3): 309 - 311.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.