Skip Navigation



Radiation Protection Dosimetry Advance Access published online on July 11, 2006

Radiation Protection Dosimetry, doi:10.1093/rpd/ncj012
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
120/1-4/303    most recent
ncj012v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Velbeck, K. J.
Right arrow Articles by Streetz, K. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Velbeck, K. J.
Right arrow Articles by Streetz, K. L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

SSD 2004 Special Issue Articles

TYPE TESTING THE MODEL 6600 PLUS AUTOMATIC TLD READER

K. J. Velbeck 1 *, L. Z. Luo 1, and K. L. Streetz 1

1 Thermo Electron Corporation, 26400 Broadway Avenue, Oakwood Village, OH 44146, USA

* To whom correspondence should be addressed.
K. J. Velbeck, E-mail: Kenneth.Velbeck{at}thermo.com


   Abstract

The Harshaw Model 6600 Plus is a reader with a capacity for 200 TLD cards or 800 extremity cards. The new unit integrates more functionality, and significantly automates the QC and calibration process compared to the Model 6600. The Model 6600 Plus was tested against the IEC 61066 (1991-2012) procedures using Harshaw TLD-700H and TLD-600H, LiF:Mg,Cu,P based TLD Cards. An overview of the type testing procedures is presented. These include batch homogeneity, detection threshold, reproducibility, linearity, self-irradiation, residue, light effects on dosemeter, light leakage to reader, voltage and frequency, dropping and reader stability. The new TLD reader was found to meet all the IEC criteria by large margins and appears well suited for whole body, extremity and environmental dosimetry applications, with a high degree of dosimetric performance.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.