Skip Navigation



Radiation Protection Dosimetry Advance Access published online on February 3, 2006

Radiation Protection Dosimetry, doi:10.1093/rpd/nci762
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
117/1-3/313    most recent
nci762v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Doyle, P.
Right arrow Articles by Finney, L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Doyle, P.
Right arrow Articles by Finney, L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Leuvens Special Issue Article

PERFORMANCE EVALUATION AND TESTING OF DIGITAL INTRA-ORAL RADIOGRAPHIC SYSTEMS

P. Doyle 1 * and L. Finney 1

1 Health Physics, Department of Clinical Physics and Bio-Engineering, Gartnavel Royal Hospital, Glasgow G12 OXH, UK

* To whom correspondence should be addressed.
P. Doyle, E-mail: philip.doyle{at}northglasgow.scot.nhs.uk


   Abstract

Four digital intra-oral radiographic systems were tested and evaluated; three charge-coupled device (CCD) based systems from RVG, Visualix and Sidexis and a photostimulable phosphor (PSP) system from DenOptix. Image quality was assessed using three purpose-built phantoms to measure uniformity, low contrast detail detectability and signal-to-noise ratio (SNR). Limiting resolution was measured using a 20 lp mm-1 bar pattern. Radiation output inaccuracies caused difficulties in achieving optimum doses for CCD systems. However, the accuracy was improved by using K-edge filters. SNR measurements proved to be a useful tool in assessing system performance. Each system has specific attributes: resolution was highest for the RVG system, the Visualix system measured the highest SNR and the lowest exposure settings were on the Sidexis system. Test methods and phantoms developed are suitable for acceptance testing and commissioning digital dental X-ray systems and for programming each system to produce an optimum level of image quality.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.