Skip Navigation



Radiation Protection Dosimetry Advance Access published online on February 3, 2006

Radiation Protection Dosimetry, doi:10.1093/rpd/nci746
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
117/1-3/93    most recent
nci746v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Tsapaki, V.
Right arrow Articles by Neofotistou, V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsapaki, V.
Right arrow Articles by Neofotistou, V.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Leuvens Special Issue Article

COMPARISON OF A CCD AND A FLAT-PANEL DIGITAL SYSTEM IN AN INTERVENTIONAL CARDIOLOGY LABORATORY

V. Tsapaki 1, S. Kottou 2 *, N. Kollaros 3, Z. Kyriakidis 3, and V. Neofotistou 4

1 Medical Physics Department, Konstantopoulio Agia Olga Hospital, 3-5 Agias Olgas, Nea Ionia, 14233 Athens, Greece
2 Medical Physics Department, Medical School, Athens University, 75 Mikras Asias Str, 11527 Athens, Greece
3 Cardiology Department, Onassis Cardiac Surgery Center, 356 Sygrou Avenue, 17674 Athens, Greece
4 Medical Physics Department, Regional Athens General Hospital ‘G.Gennimatas’, 154 Mesogeion Avenue, 11527 Athens, Greece

* To whom correspondence should be addressed.
S. Kottou, E-mail: skottou{at}med.uoa.gr


   Abstract

We evaluated the performances of angiographic units equipped with a flat-panel (FP) detector and image intensifier (II) charge-coupled device (CCD) in the Interventional Cardiology (IC) Department. Entrance dose rate and dose per image, along with the dose at the II level were measured using 2 mm copper sheets to simulate a patient. Image quality (IQ) was evaluated using a phantom. Doses increased with fluoroscopy level changing from low to high. FP presented higher doses than CCD. Periodic measurements showed differences of up to 35%. Low mode IQ did not significantly differ from normal and high mode for both systems. Low fluoroscopy mode was decided to be used routinely. Both X-ray systems performed within international recommendations for conventional systems with the exception of higher cine radiation doses and II dose rates, stressing the fact that more studies are required to investigate whether dose levels should be adjusted.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Br. J. Radiol.Home page
V TSAPAKI, P N MANIATIS, A MAGGINAS, V VOUDRIS, S PATSILINAKOS, T VRANZTA, E VANO, and D S COKKINOS
What are the clinical and technical factors that influence the kerma-area product in percutaneous coronary intervention?
Br. J. Radiol., December 1, 2008; 81(972): 940 - 945.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
I. Mavrikou, S. Kottou, V. Tsapaki, and V. Neofotistou
HIGH PATIENT DOSES IN INTERVENTIONAL CARDIOLOGY DUE TO PHYSICIANS' NEGLIGENCE: HOW CAN THEY BE PREVENTED?
Radiat Prot Dosimetry, March 12, 2008; (2008) ncn005v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
V. Tsapaki, S. Patsilinakos, V. Voudris, A. Magginas, S. Pavlidis, T. Maounis, G. Theodorakis, M. Koutelou, T. Vrantza, M. Nearchou, et al.
Level of patient and operator dose in the largest cardiac centre in Greece
Radiat Prot Dosimetry, March 1, 2008; 129(1-3): 71 - 73.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
V. Tsapaki, R. Padovani, E. Vano, A. Schreiner, M. Molfetas, V. Neofotistou, and S. Kottou
Commissioning and constancy protocols for digital angiographic units
Radiat Prot Dosimetry, March 1, 2008; 129(1-3): 258 - 260.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
R. Padovani, A. Trianni, C. Bokou, H. Bosmans, J. Jankowski, S. Kottou, K. Kepler, J. Malone, V. Tsapaki, D. Salat, et al.
Survey on performance assessment of cardiac angiography systems
Radiat Prot Dosimetry, March 1, 2008; 129(1-3): 108 - 111.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.