Skip Navigation


Radiation Protection Dosimetry Advance Access first published online on February 3, 2006
This version published online on February 4, 2006

Radiation Protection Dosimetry, doi:10.1093/rpd/nci727
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
117/1-3/139    most recent
nci727v2
nci727v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Schreiner-Karoussou, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schreiner-Karoussou, A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Leuvens Special Issue Article

DOSE OPTIMISATION IN COMPUTED RADIOGRAPHY

A. Schreiner-Karoussou 1 *

1 Direction de la Santé, Division de la Radioprotection, Villa Louvigny, L-2120 Luxembourg

* To whom correspondence should be addressed.
A. Schreiner-Karoussou, E-mail: alexandra.schreiner{at}ms.etat.lu


   Abstract

After the installation of computed radiography (CR) systems in three hospitals in Luxembourg a patient dose survey was carried out for three radiographic examinations, thorax, pelvis and lumbar spine. It was found that the patient doses had changed in comparison with the patient doses measured for conventional radiography in the same three hospitals. A close collaboration between the manufacturers of the X-ray installations, the CR imaging systems and the medical physicists led to the discovery that the speed class with which each radiographic examination was to be performed, had been ignored, during installation of the digital imaging systems. A number of procedures were carried out in order to calibrate and program the X-ray installations in conjunction with the CR systems. Following this optimisation procedure, a new patient dose survey was carried out for the three radiographic examinations. It was found that patient doses for the three hospitals were reduced.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
I. A. Tsalafoutas, G. A. Blastaris, A. S. Moutsatsos, P. S. Chios, and E. P. Efstathopoulos
Correlation of image quality with exposure index and processing protocol in a computed radiography system
Radiat Prot Dosimetry, June 1, 2008; 130(2): 162 - 171.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
P. L. Kleinman, D. Zurakowski, K. J. Strauss, R. H. Cleveland, J. M. Perez-Rosello, D. P. Nichols, K. H. Zou, and P. K. Kleinman
Detection of Simulated Inflicted Metaphyseal Fractures in a Fetal Pig Model: Image Optimization and Dose Reduction with Computed Radiography
Radiology, May 1, 2008; 247(2): 381 - 390.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.