Skip Navigation



Radiation Protection Dosimetry Advance Access published online on February 7, 2006

Radiation Protection Dosimetry, doi:10.1093/rpd/nci720
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
117/1-3/131    most recent
nci720v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Vassileva, J.
Right arrow Articles by Karadjov, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vassileva, J.
Right arrow Articles by Karadjov, A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Leuvens Special Issue Article

BULGARIAN EXPERIENCE IN THE ESTABLISHMENT OF REFERENCE DOSE LEVELS AND IMPLEMENTATION OF A QUALITY CONTROL SYSTEM IN DIAGNOSTIC RADIOLOGY

J. Vassileva 1 *, A. Dimov 1, A. Slavchev 1, and A. Karadjov 1

1 National Center of Radiobiology and Radiation Protection, 132 Kliment Uhridsky Boulevard, Sofia 1756, Bulgaria

* To whom correspondence should be addressed.
J. Vassileva, E-mail: j.vassileva{at}ncrrp.org


   Abstract

Results from a Bulgarian patient dose survey in diagnostic radiology are presented. Reference levels for entrance surface dose (ESD) were 0.9 mGy for chest radiography (PA), 30 mGy for lumbar spine (Lat), 10 mGy for pelvis, 5 mGy for skull (AP), 3 mGy for skull (Lat) and 13 mGy for mammography. Quality control (QC) programmes were proposed for various areas of diagnostic radiology. Film processing QC warranted special attention. Proposed QC programmes included parameters to be tested, level of expertise needed and two action levels: remedial and suspension. Programmes were tested under clinical conditions to assess initial results and draw conclusions for further QC system development. On the basis of international experience, measurement protocols were developed for all parameters tested. QC equipment was provided as part of the PHARE project. A future problem for QC programme implementation may be the small number of medical physics experts in diagnostic radiology.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.