Skip Navigation



Radiation Protection Dosimetry Advance Access published online on February 3, 2006

Radiation Protection Dosimetry, doi:10.1093/rpd/nci704
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
117/1-3/263    most recent
nci704v2
nci704v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Bernardi, G.
Right arrow Articles by Vano, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bernardi, G.
Right arrow Articles by Vano, E.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

SCIENTIFIC AND TECHNICAL PAPER

A STUDY TO VALIDATE THE METHOD BASED ON DIMOND QUALITY CRITERIA FOR CARDIAC ANGIOGRAPHIC IMAGES

G. Bernardi 1 *, R. Padovani 2, W. Desmet 3, A. Peterzol 2, J. D. Giannuleas 4, E. Neofotistou 5, A. Manginas 6, Z. Olivari 7, J. Cosgrave 8, F. Alfonso 9, J. Garcia 9, H. Bosmans 10, A. Dowling 11, H. S. Toh 1, G. Morocutti 1, and E. Vano 12

1 Unità Operativa di Cardiologia, Az. Osp. S. Maria della Misericordia, Piazzale della Misericordia, 15, 33100 Udine, Italy
2 Unità Operativa di Fisica Sanitaria, Az. Osp. S. Maria della Misericordia, Piazzale della Misericordia, 15, 33100 Udine, Italy
3 Cardiology Department, Gasthuisberg University Hospital (GUH), Herestraat 49 B, 3000 Leuven, Belgium
4 Cardiology Department, Athens General Regional Hospital (AGRH), 154 Mesogion Avenue, 11527 Athens, Greece
5 Medical Physics Department, Athens General Regional Hospital (AGRH), 154 Mesogion Avenue, 11527 Athens, Greece
6 Cardiology Department, Onassis Cardiac Surgery Centre (OCSC), 356 Sygrou Avenue, 17674 Athens, Greece
7 Cardiology Department, Az. Osp. Ca Foncello (AOCF), Piazza Ospedale 1, 31100 Treviso, Italy
8 Cardiology Department, St James Hospital (SJH), P.O. Box 580 James's Street, Dublin 8, Ireland
9 Cardiology Department, San Carlos University Hospital (SCUH), Complutense University, Madrid 28040, Spain
10 Medical Physics in Radiology, Gasthuisberg University Hospital (GUH), Herestraat 49 B, 3000 Leuven, Belgium
11 Medical Physics Department, St James Hospital (SJH), P.O. Box 580 James's Street, Dublin 8, Ireland
12 Medical Physics Department, San Carlos University Hospital (SCUH), Complutense University, Madrid 28040, Spain

* To whom correspondence should be addressed.
G. Bernardi, E-mail: guglbern{at}tin.it


   Abstract

A method based on image quality criteria (QC) for cine-angiography was developed to measure the quality of cine-angiograms (CA). A series of 30 CA for left ventriculography (LV) and left and right coronary angiography (LCA, RCA) have been scored and 172 readings were obtained. Standard deviation of quality scores indicated the reproducibility of the method. Each part of CA was examined separately, giving scores for LV, LCA and RCA and a total score (TS), with clinical (C) and technical (T) criteria defined and examined separately. In 83% of the studies TS was >0.8 and with standard deviation from 0.02 to 0.21. In general, LV had a lower score and greater disagreement compared with RCA and LCA. Disagreement was greater in T, compared with C. In conclusion, these results indicate that QC, translated into a scoring system, yields reproducible data on the quality of cardiac images.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
G. Bernardi, O. Bar, T. Jezewski, E. Vano, C. Maccia, A. Trianni, and R. Padovani
Quality criteria for cardiac images: an update
Radiat Prot Dosimetry, March 1, 2008; 129(1-3): 87 - 90.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.