Skip Navigation



Radiation Protection Dosimetry Advance Access published online on May 24, 2005

Radiation Protection Dosimetry, doi:10.1093/rpd/nch499
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
114/4/481    most recent
nch499v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Takada, M.
Right arrow Articles by Fujitaka, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Takada, M.
Right arrow Articles by Fujitaka, K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2005. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oupjournals.org
Received January 13, 2005
Revised April 15, 2005
Accepted April 23, 2005

SCIENTIFIC AND TECHNICAL PAPER

DIFFERENTIAL ABSORBED DOSE DISTRIBUTIONS IN LINEAL ENERGY FOR NEUTRONS AND GAMMA RAYS AT THE MONO-ENERGETIC NEUTRON CALIBRATION FACILITY

M. Takada 1*, M. Baba 2, H. Yamaguchi 1, and K. Fujitaka 1

1 National Institute of Radiological Sciences, Chiba 263-8555, Japan
2 Cyclotron and Radioisotope Center, Tohoku University, Sendai 980-8579, Japan

* To whom correspondence should be addressed.
M. Takada, E-mail: m_takada{at}nirs.go.jp


   Abstract

Absorbed dose distributions in lineal energy for neutrons and gamma rays of mono-energetic neutron sources from 140 keV to 15 MeV were measured in the Fast Neutron Laboratory at Tohoku University. By using both a tissue-equivalent plastic walled counter and a graphite-walled low-pressure proportional counter, absorbed dose distributions in lineal energy for neutrons were obtained separately from those for gamma rays. This method needs no knowledge of energy spectra and dose distributions for gamma rays. The gamma-ray contribution in this neutron calibration field >1 MeV neutron was <3%, while for <550 keV it was >40%. The measured neutron absolute absorbed doses per unit neutron fluence agreed with the LA150 evaluated kerma factors. By using this method, absorbed dose distributions in lineal energy for neutrons and gamma rays in an unknown neutron field can be obtained separately.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
S. Tsuda, Y. Nakane, and Y. Yamaguchi
Calculation of energy distributions of charged particles produced by neutrons from 0.14 to 65 MeV in tissue substitutes
Radiat Prot Dosimetry, August 1, 2007; 126(1-4): 174 - 177.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.