Skip Navigation



Radiation Protection Dosimetry Advance Access published online on November 30, 2004

Radiation Protection Dosimetry, doi:10.1093/rpd/nch432
Copyright © 2004 Oxford University Press.
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
113/1/54    most recent
nch432v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Compagnone, G.
Right arrow Articles by Bergamini, C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Compagnone, G.
Right arrow Articles by Bergamini, C.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Received June 30, 2004
Revised September 15, 2004
Accepted November 3, 2004

SCIENTIFIC AND TECHNICAL PAPER

LOCAL DIAGNOSTIC REFERENCE LEVELS IN STANDARD X-RAY EXAMINATIONS

Gaetano Compagnone 1*, Laura Pagan 1, and Carlo Bergamini 1

1 Medical Physics Department, S. Orsola-Malpighi Hospital, Via Massarenti 9, 40138 Bologna, Italy

* To whom correspondence should be addressed.
Gaetano Compagnone, E-mail: gcompa{at}med.unibo.it


   Abstract

The national diagnostic reference levels (NDRLs) form an efficient, concise and powerful standard for optimising radiation protection of a patient. However, in a large hospital, where many radiological departments are present, it is also possible to calculate and define lower dose values as local diagnostic reference levels (LDRLs). In our hospital there are eight radiological departments; in each of these, the entrance skin dose (ESD) distributions were determined for 10 standard projections (AP Abdomen, PA and LAT Chest, AP and LAT Lumbar Spine, LAT Lumbo-Sacral Joint, AP Pelvis, PA and LAT Skull and AP Urinary tract) and then the ESDs were compared with data previously published and with Italian NDRLs. All ESD values were below the corresponding NDRLs. The maximum/minimum ratio of ESDs ranged from 3.9 (LAT Skull) to 34.3 (AP Abdomen) for individual adult patients and from 2.1 (PA Skull) to 6.5 (Urinary tract) across the mean values of the radiological departments. Finally, it is shown how LDRLs can be proposed to obtain a more fully optimised radiation protection of patients.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
G. Compagnone, L. Pagan, M. C. Baleni, F. L. Calzolaio, L. Barozzi, and C. Bergamini
Patient dose in digital projection radiography
Radiat Prot Dosimetry, March 1, 2008; 129(1-3): 135 - 137.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
G Compagnone, M C. Baleni, L Pagan, F L Calzolaio, L Barozzi, and C Bergamini
Comparison of radiation doses to patients undergoing standard radiographic examinations with conventional screen-film radiography, computed radiography and direct digital radiography.
Br. J. Radiol., November 1, 2006; 79(947): 899 - 904.
[Abstract] [Full Text] [PDF]


Home page
radtechHome page
E. SEERAM and P. C. BRENNAN
Diagnostic Reference Levels In Radiology.
Radiol. Technol., May 1, 2006; 77(5): 373 - 384.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.