Skip Navigation



Radiation Protection Dosimetry Advance Access published online on July 20, 2004

Radiation Protection Dosimetry, doi:10.1093/rpd/nch043
Copyright © 2004 Oxford University Press.
This Article
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
111/2/173    most recent
nch043v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Ródenas, J.
Right arrow Articles by Sánchez-Mayoral, M. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ródenas, J.
Right arrow Articles by Sánchez-Mayoral, M. L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Received January 3, 2003
Revised March 1, 2004
Accepted March 4, 2004

SCIENTIFIC AND TECHNICAL PAPER

DEVELOPING A VIRTUAL REALITY APPLICATION FOR TRAINING NUCLEAR POWER PLANT OPERATORS: SETTING UP A DATABASE CONTAINING DOSE RATES IN THE REFUELLING PLANT

J. Ródenas 1*, I. Zarza 1, M. C. Burgos 1, A. Felipe 2, M. L. Sánchez-Mayoral 2

1 Departamento de Ingeniería Química y Nuclear, Universidad Politécnica de Valencia, Apartado 22012 E-46071 Valencia, Spain
2 IBERINCO, Departamento de Generación Nuclear, Av. de Burgos, 8B (Edif. Génesis) 28036 Madrid, Spain

* To whom correspondence should be addressed. E-mail: jrodenas{at}iqn.upv.es.


   Abstract

Operators in Nuclear Power Plants can receive high doses during refuelling operations. A training programme for simulating refuelling operations will be useful in reducing the doses received by workers as well as minimising operation time. With this goal in mind, a virtual reality application is developed within the framework of the CIPRES project. The application requires doses, both instantaneous and accumulated, to be displayed at all times during operator training. Therefore, it is necessary to set up a database containing dose rates at every point in the refuelling plant. This database is based on radiological protection surveillance data measured in the plant during refuelling operations. Some interpolation routines have been used to estimate doses through the refuelling plant. Different assumptions have been adopted in order to perform the interpolation and obtain consistent data. In this paper, the procedures developed to set up the dose database for the virtual reality application are presented and analysed.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.