Radiation Protection Dosimetry 96:261-264 (2001)
© 2001 Oxford University Press
Electronic Neutron Personal Dosimetry with Superheated Drop Detectors
The prototype of an electronic personal neutron dosemeter based on superheated drop detectors is presented. This battery operated device comprises a neutron sensor, bubble-counting electronics and a temperature controller ensuring an optimal dose equivalent response. The neutron sensor is a 12 ml detector vial containing an emulsion of about 50,000 halocarbon-12 droplets of 100 µm diameter. The temperature controller is a low-power, solid-state device stabilising the emulsion at 31.5 oC by means of an etched foil heater. The microprocessor-controlled counting electronics relies on a double piezo-electric transducer configuration to record bubble formation acoustically via a comparative pulse-shape analysis of ambient noise and detector signals. The performance of the dosemeter was analysed in terms of the requirements presently developed for neutron personal dosemeters. The detection threshold is about 1 µSv, while the personal dose equivalent response to neutrons in the thermal to 62 MeV range falls within a factor 1.6 of 13 bubbles per µSv.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
C. Taylor, D. Montvila, D. Flynn, C. Brennan, and F. d'Errico An acoustical bubble counter for superheated drop detectors Radiat Prot Dosimetry, September 1, 2006; 120(1-4): 514 - 517. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Bolognese-Milsztajn, M. Ginjaume, M. Luszik-Bhadra, F. Vanhavere, W. Wahl, and A. Weeks Active personal dosemeters for individual monitoring and other new developments Radiat Prot Dosimetry, November 22, 2004; 112(1): 141 - 168. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Das, T. Sawamura, M. Abe, J. H. Kaneko, A. Homma, F. Fujita, S. Tsuda, and T. Nishitani Superheated emulsions as high-energy neutron dosemeters Radiat Prot Dosimetry, August 1, 2004; 110(1-4): 325 - 331. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Luszik-Bhadra Electronic personal dosemeters: the solution to problems of individual monitoring in mixed neutron/photon fields? Radiat Prot Dosimetry, August 1, 2004; 110(1-4): 747 - 752. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Bolognese-Milsztajn, D. Bartlett, M. Boschung, M. Coeck, G. Curzio, F. d'Errico, A. Fiechtner, V. Giusti, V. Gressier, J. Kyllonen, et al. Individual neutron monitoring in workplaces with mixed neutron/photon radiation Radiat Prot Dosimetry, August 1, 2004; 110(1-4): 753 - 758. [Abstract] [Full Text] [PDF] |
||||