Radiation Protection Dosimetry 96:213-217 (2001)
© 2001 Oxford University Press
Mixed High Energy Photon and Electron Radiation Fields for Calibrating Radiation Protection Dosemeters
According to ISO 4037-3, calibrations of radiation protection dosemeters with photon radiation of energies above 3 MeV are performed under conditions of charged particle equilibrium. No information is provided concerning how to determine the response of dosemeters to radiation fields in the more general case when these conditions are not fulfilled. This paper deals with the production of mixed high energy photon and electron fields characterised by a lack or an excess of charged particles relative to conditions of equilibrium and describes a new procedure for the dosimetry in such fields. Through variation of the charged particle fluence fraction with respect to a nearly constant photon fluence, Hp(10) and H'(10) values varied by up to a factor of 1.74. The above mentioned basic study was utilised in the recent IAEA intercomparison (Co-ordinated Research Project 1996-1998) and EURADOS 'trial performance test' (1996-1998) for individual monitoring of photon radiation in testing response characteristics of individual dosemeters in non-charged particle equilibrium conditions.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
R. Behrens and S. Rottger CHARACTERISATION OF THREE HIGH-ENERGY PHOTON AND FAST NEUTRON REFERENCE RADIATION FIELDS Radiat Prot Dosimetry, January 8, 2009; (2009) ncn306v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Wissmann Long-term measurements of H*(10) at aviation altitudes in the northern hemisphere Radiat Prot Dosimetry, December 1, 2006; 121(4): 347 - 357. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Wissmann Variations observed in environmental radiation at ground level Radiat Prot Dosimetry, April 1, 2006; 118(1): 3 - 10. [Abstract] [Full Text] [PDF] |
||||