Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (29)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Bordy, J.M.
Right arrow Articles by Hyvönen, H.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Bordy, J.M.
Right arrow Articles by Hyvönen, H.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Radiation Protection Dosimetry 89:107-154 (2000)
© 2000 Oxford University Press

Performance Test of Dosimetric Services in the EU Member States and Switzerland for the Routine Assessment of Individual Doses (Photon, Beta and Neutron)

J.M. Bordy, H. Stadtmann, P. Ambrosi, D.T. Bartlett, P. Christensen, T. Colgand and H. Hyvönen (INVITED)

The results are given of a consolidated performance test for whole-body, and extremity personal dosemeters broadly representative of those in use in the EU member states and Switzerland. Beta, photon and neutron personal dosemeters were used to assess the routine services ability to determine and report personal dose equivalents. In total, 69 sets of dosemeters were entered in the test by 34 services. About 1000 dosemeters were irradiated. One purpose of the consolidated performance test and the analysis of the results was to enable the assessment of criteria for the acceptability of the dosimetry of routine services. It was assumed that each service would have already done a type test before performing routine dosimetry; the radiation fields were chosen to simulate, as far as possible, workplace radiation fields by mixing combining energies and incident angles. The results of photon dosemeters were good for all fields except for R-F. Beta test results showed that many types of dosemeter were not able accurately to determine personal dose equivalent when large incident angles and low energies were encountered. Neutron dosimetry results were very dependent on the dosemeter type and the dose calculation algorithm. Fast neutron fields were generally well measured, but particular problems were noted in the determination of intermediate energy fields. This illustrates the importance of such a field for calibration purposes. Of particular concern from a radiological protection point of view was the large number of results for beta and neutron dosemeters underestimating personal dose equivalent. A considerable over-response was noted in few cases. This is one of three papers produced by the EURADOS action group. Harmonisation and Dosimetric Quality Assurance in Individual Monitoring for External Radiation. The other two papers are included in this issue of Radiation Protection Dosimetry.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
JOURNAL OF THE ICRUHome page
REFERENCES
J. ICRU, December 1, 2006; 6(2): 47 - 50.
[Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
J. W. E. van Dijk
On the assessment of the performance of personal dosemeters and individual monitoring services
Radiat Prot Dosimetry, September 1, 2006; 120(1-4): 250 - 258.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
B. Morelli, F. Mariotti, and E. Fantuzzi
The ENEA neutron personal dosimetry service
Radiat Prot Dosimetry, September 1, 2006; 120(1-4): 312 - 315.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
M. Ginjaume, S. Perez, X. Ortega, and M. A. Duch
Comparison of two extremity dosemeters based on LiF:Mg,Cu,P thin detectors for mixed beta-gamma fields
Radiat Prot Dosimetry, September 1, 2006; 120(1-4): 316 - 320.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
F. Vanhavere, D. Berus, N. Buls, and P. Covens
The use of extremity dosemeters in a hospital environment
Radiat Prot Dosimetry, May 1, 2006; 118(2): 190 - 195.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
M. A. Lopez Ponte, C. M. Castellani, L. Currivan, J. W. E. VanDijk, R. Falk, P. Olko, and C. Wernli
A catalogue of dosemeters and dosimetric services within Europe--an update
Radiat Prot Dosimetry, November 22, 2004; 112(1): 45 - 68.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.