Radiation Protection Dosimetry 82:105-114 (1999)
© 1999 Oxford University Press
Dosimetry of Occupationally Exposed Persons in Diagnostic and Interventional Arteriography. Part 2: Assessment of Effective Dose
This study aimed to quantify effective dose (E) for occupationally exposed persons (workers) in diagnostic and interventional arteriography. Using Monte Carlo radiation transport calculation, new air kerma to organ dose conversion coefficients (DCCs) were determined. Taking attenuation by protective clothing into account, E was estimated from the DCCs and entrance doses measured at forehead, neck, thorax, abdomen, upper arms, hands and lower legs of the workers. Average E was calculated for several types of procedures and for three hospitals. For operators, E was between 0.5 and 7 µSv per procedure for undercouch X ray tubes and between 0.8 and 22 µSv for overcouch tubes. For assistants, E was typically a factor of two lower. Wearing a thyroid collar roughly reduced E by 50%. These values are low, which is due, among other things, to the nearly general use of a mechanical contrast injector and an undercouch X ray tube.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
K. P. Kim and D. L. Miller MINIMISING RADIATION EXPOSURE TO PHYSICIANS PERFORMING FLUOROSCOPICALLY GUIDED CARDIAC CATHETERISATION PROCEDURES: A REVIEW Radiat Prot Dosimetry, March 27, 2009; (2009) ncp052v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. O. Lie, G. U. Paulsen, and T. Wohni ASSESSMENT OF EFFECTIVE DOSE AND DOSE TO THE LENS OF THE EYE FOR THE INTERVENTIONAL CARDIOLOGIST Radiat Prot Dosimetry, December 4, 2008; (2008) ncn296v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Jarvinen, N. Buls, P. Clerinx, J. Jansen, S. Miljanic, D. Nikodemova, M. Ranogajec-Komor, and F. d'Errico OVERVIEW OF DOUBLE DOSIMETRY PROCEDURES FOR THE DETERMINATION OF THE EFFECTIVE DOSE TO THE INTERVENTIONAL RADIOLOGY STAFF Radiat Prot Dosimetry, May 14, 2008; (2008) ncn082v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
T Siiskonen, M Tapiovaara, A Kosunen, M Lehtinen, and E Vartiainen Monte Carlo simulations of occupational radiation doses in interventional radiology Br. J. Radiol., June 1, 2007; 80(954): 460 - 468. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Bor, S. Cekirge, T. Turkay, O. Turan, M. Gulay, E. Onal, and B. Cil Patient and staff doses in interventional neuroradiology Radiat Prot Dosimetry, December 1, 2005; 117(1-3): 62 - 68. [Abstract] [Full Text] [PDF] |
||||
![]() |
E K Osei and C J Kotre Equivalent dose to the fetus from occupational exposure of pregnant staff in diagnostic radiology Br. J. Radiol., July 1, 2001; 74(883): 629 - 637. [Abstract] [Full Text] [PDF] |
||||
![]() |
G J Kemerink, A C W Borstlap, M J Frantzen, F W Schultz, J Zoetelief, and J M A van Engelshoven Patient and occupational dosimetry in double contrast barium enema examinations Br. J. Radiol., May 1, 2001; 74(881): 420 - 428. [Abstract] [Full Text] [PDF] |
||||