Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on April 1, 2008
Radiation Protection Dosimetry 2008 129(1-3):346-349; doi:10.1093/rpd/ncn084
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
129/1-3/346    most recent
ncn084v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Milu, C.
Right arrow Articles by Dumitrescu, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Milu, C.
Right arrow Articles by Dumitrescu, A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2008. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Some aspects on radiation protection in conventional and digital radiology in Romania

Constantin Milu* and Alina Dumitrescu

Institute of Public Health, Str.dr.Leonte No. 1-3, Bucharest 35, Romania

* Corresponding author: cmilu{at}ispb.ro

Since 1965, medical radiation exposure in the population of Romania has been evaluated by the Network of Radiation Hygiene Laboratories of the Ministry of Public Health, including 23 laboratories throughout the whole country; the network is co-ordinated by the Institute of Public Health Bucharest. In Romania, for a population of 22.5 million inhabitants, 465 X-ray examinations were reported during the last survey, the most frequent being chest examination. There was no specific reference to digital radiology. Digital radiology has been introduced only recently in Romania, and only some rough data on the situation can be presented. Siemens AG is now present in Romania with 23 installations, type SIEREGRAPH CF and AXIOM ICONOS. A digital image intensifier technique is used only for fluoroscopy, and radiography is performed using a conventional film/screen combination. The company Philips has nine installations for angiography, model INTEGRIS, and uses a computed radiography technique. Several direct digital radiography MULTISYSTEM SWISSRAY installations (about 40 units) are also available for adult and paediatric examinations. The Council Directive 97/43/EURATOM on health protection of individuals against dangers of ionising radiation in relation to medical exposure was fully transformed into Romanian legislation in 2002.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.