Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on March 4, 2008
Radiation Protection Dosimetry 2008 129(1-3):328-332; doi:10.1093/rpd/ncn018
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
129/1-3/328    most recent
ncn018v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Jankowski, J.
Right arrow Articles by Faulkner, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jankowski, J.
Right arrow Articles by Faulkner, K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2008. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

An international calibration of Kerma–Area Product meters for patient dose optimisation study

J. Jankowski1,*, J. Domienik1, S. Papierz1, R. Padovani2, E. Vano3 and K. Faulkner4

1 Nofer Institute of Occupational Medicine (NIOM), Lodz, Poland
2 Medical Physics and Cardiology Department, S. Maria Hospital, Udine, Italy
3 Radiology Department, Faculty of Medicine, Complutenese University, Madrid, Spain
4 QARC, Wallsend, Newcastle, UK

* Corresponding author: jjan{at}imp.lodz.pl

The results of international calibration of Kerma Area Product (KAP) meters for European SENTINEL survey on patient dose optimisation of cardiac and interventional radiology practice are presented. Twelve countries were involved in the study. An investigation was conduced on 25 KAP meters fitted to undercouch X-ray tubes; 13 KAP meters were installed on cardiac units and the remaining 12 on interventional ones. The simplified calibration method has been applied, consisting of KAP estimation by multiplying the air kerma at the centre of the X-ray field by the irradiated area. The obtained values of calibration factors range from 0.4 to 0.9 and from 0.4 to 0.8 for KAP meters installed on cardiac and interventional units, respectively. They account also for table and mattress attenuation. For air kerma assessment, measurements with thermoluminescent dosemeters have been applied and when possible compared against an additional reference dosemeter. As the result of the investigation, the importance of calibration of KAP meters in clinical conditions that include mattress and table attenuation has been recognised.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.