Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on March 8, 2008
Radiation Protection Dosimetry 2008 129(1-3):29-31; doi:10.1093/rpd/ncn007
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
129/1-3/29    most recent
ncn007v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Tsapaki, V.
Right arrow Articles by Papailiou, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tsapaki, V.
Right arrow Articles by Papailiou, J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2008. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Patient skin dose assessment during CT-guided interventional procedures

V. Tsapaki1,4,*, C. Triantopoulou1, P. Maniatis1, S. Kottou2, J. Tsalafoutas3 and J. Papailiou1

1 Konstantopoulio Hospital, 3-5 Agias Olgas Str., Nea Ionia, Athens, Greece
2 Department of Medical Physics, Medical School, University of Athens, 75 Mikras Asias Str., Athens, Greece
3 Department of Medical Physics, Agios Savvas Hospital, 171 Alexandras Avenue, Athens, Greece

* Corresponding author: virginia{at}otenet.gr

The purpose of this study was to investigate patient skin doses in the most frequent computed tomography-guided interventional radiology procedures. The study includes 14 abdominal biopsies and 15 radiofrequency (RF) ablations. Patient skin dose was assessed by slow verification films. The technical factors recorded were: tube kilovoltage (kVp), tube load (mAs), slice thickness and the total number of slices (S). The median value of maximum entrance skin dose (ESDM) in biopsy was 108 mGy (9.5–282 mGy). S had a range of 4–152 with a median of 44 slices. Significant correlation was found between S and dose (r = 0.80). Median ESDM in RF ablation was 238 mGy (104–500 mGy). S had a range of 108–175 with a median of 155 slices. No significant correlation was found between S and dose. The large range of results show that a more extensive investigation should be performed. In summary, diagnostic procedures such as biopsy present patient skin doses that are relatively low. On the other hand, patient skin dose in RF ablation can be high and can reach values higher than the value that a slow verification film is capable of measuring (1.2 Gy). For these procedures, an alternative method should be investigated.


4 Present address: 1 Ifaistou str., 14569 Anixi, Athens, Greece.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.