Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on March 4, 2008
Radiation Protection Dosimetry 2008 129(1-3):265-270; doi:10.1093/rpd/ncn029
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
129/1-3/265    most recent
ncn029v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Van Ongeval, C.
Right arrow Articles by Marchal, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Van Ongeval, C.
Right arrow Articles by Marchal, G.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2008. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Clinical image quality criteria for full field digital mammography: a first practical application

Chantal Van Ongeval1,*, André Van Steen1, Catherine Geniets1, Frederik Dekeyzer2, Hilde Bosmans2 and Guy Marchal1

1 Department of Radiology, UZ Leuven, campus Gasthuisberg, 3000 Leuven, Belgium
2 Center of Medical Physics in Radiology, UZ Leuven, campus Gasthuisberg, 3000 Leuven, Belgium

* Corresponding author: chantal.vanongeval{at}uzleuven.be

In order to quantify the clinical quality of full-field digital mammography, a set of image quality parameters is developed. The set consisted of 12 image quality criteria and 8 physical characteristics of the image. The first set interrogates the visibility of anatomical structures and typical characteristics of a digital image, such as noise and saturation of dark and white areas. The second set of criteria evaluates contrast, sharpness and confidence with the representation of masses, microcalcifications and the image. The use of these criteria is reported in a retrospective study, in which the impact of dose on the radiological quality of digital mammograms is evaluated. Fifty patients acquired in a low-dose mode were retrieved and compared with 50 patients acquired in a dose mode that was set 41% higher. The dose affects, more than expected, contrast and sharpness of the image, whereas the visibility of the anatomical structures remains unchanged. With these parameters, quantification of the image quality is possible; however, because of subjectivity of the parameters, only intra-observer comparison and evaluation of the individual parameters rather than the overall results are advised. Together with physical tests of image quality, critical radiological evaluation of the quality should be included in the acceptance process of digital mammography.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
JOURNAL OF THE ICRUHome page
References
J. ICRU, December 1, 2009; 9(2): 89 - 104.
[PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.