Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on March 28, 2008
Radiation Protection Dosimetry 2008 129(1-3):170-172; doi:10.1093/rpd/ncn080
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
129/1-3/170    most recent
ncn080v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Zdesar, U.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Zdesar, U.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2008. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Reference levels for image quality in mammography

Urban Zdesar*

Institute of Occupational Safety, Chengdujska cesta 25, SI-1000 Ljubljana, Slovenia

* Corresponding author: urban.zdesar{at}zvd.si

Diagnostic reference levels are a well-established tool for optimisation in diagnostic radiology. A dose-reference level for certain diagnostic procedures, meant to identify practices with unusually high doses, is usually set at the third quartile of the distribution of doses in different diagnostic centres. If image quality is somehow quantified, the same ‘worst quarter’ principle can also be used to identify practices with less than optimal performance in terms of image quality. In Slovenia, the performance of mammographic centres is evaluated annually. Technical testing includes average glandular dose determination and evaluation of technical image quality using the image of a mammographic phantom. From the phantom image, simple image quality parameters are derived and for some of them reference levels can be established. In this study, the results from ten years of testing (1996–2006) at mammography centres are presented and the usefulness of reference levels is evaluated.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.