Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on March 4, 2008
Radiation Protection Dosimetry 2008 129(1-3):147-149; doi:10.1093/rpd/ncn032
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
129/1-3/147    most recent
ncn032v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Salát, D.
Right arrow Articles by Nikodemová, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Salát, D.
Right arrow Articles by Nikodemová, D.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2008. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Patient doses and image quality in digital chest radiology

D. Salát1,* and D. Nikodemová2

1 Radiation Protection Institute, Stanicna 24, 911 05 Trencin, Slovakia
2 Slovak Medical University, Limbova 12, 833 03 Bratislava, Slovakia

* Corresponding author: dusan.salat{at}medicontrol.sk

Chest X-ray examination is one of the most frequently required procedures used in clinical practice. For studying the image quality of different X-ray digital systems and for the control of patient doses during chest radiological examinations, the standard anthropomorphic lung/chest phantom RSD 330 has been used and exposed in different digital modalities available in Slovakia. To compare different techniques of chest examination, a special software has been developed that enables researchers to compare digital imaging and communications in medicine header images from different digital modalities, using a special viewer. In this paper, this special software has been used for an anonymous correspondent audit for testing image quality evaluation by comparing various parameters of chest imaging, evaluated by 84 Slovak radiologists. The results of the comparison have shown that the majority of the participating radiologists felt that the highest image quality is reached with a flat panel, assessed by the entrance surface dose value, which is approximately 75% lower than the diagnostic reference level of chest examination given in the Slovak legislation. Besides the results of the audit, the possibilities of using the software for optimisation, education and training of medical students, radiological assistants, physicists and radiologists in the field of digital radiology will be described.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.