Radiation Protection Dosimetry Advance Access originally published online on June 7, 2007
Radiation Protection Dosimetry 2007 127(1-4):93-96; doi:10.1093/rpd/ncm257
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The work of the CONRAD task group 5.2: research studies on biokinetic models
1 Federal Office for Radiation Protection, Department of Radiation Protection and Health, 85762 Oberschleißheim, Germany
2 International Atomic Energy Agency, Wagramer Straße 5, PO Box 100, 1400 Vienna, Austria
3 Health Protection Agency, Radiation Protection Division, Chilton, Didcot, Oxon OX11 0RQ, UK
4 IRSN, Radiological Protection and Human Health Division, BP17 - 92262 Fontenay-aux-Roses Cedex, France
5 University of Milan, Department of Physics and INFN, Via Celoria 16, 20133 Milano, Italy
6 GSF—National Research Center for Environment and Health, Institute of Radiation Protection—Medical Physics Group, Ingolstädter Landstr. 1, 85764 Neuherberg, Germany
7 ENEA—Radiation Protection Institute, via dei Colli 16, 40136 Bologna, Italy
8 Ukrainian Radiation Protection Institute, Melnikova 53, 04050 Kiev, Ukraine
9 CIEMAT, Avda Complutense 22, 28040 Madrid, Spain
* Corresponding author: dnosske{at}bfs.de
The objective of this Task Group is the coordination of research studies on biokinetic models and the evaluation of the implications of new biokinetic models on dose assessment and safety standards. For this the new ICRP models, which will be used for a revision of ICRP Publications 30, 54, 68 and 78, are implemented into six different computer codes in five European countries and quality assured by intercomparison procedures. The work has started with the implementation of the new ICRP Alimentary Tract Model. New systemic models and the new NCRP wound model will follow. The work also includes the evaluation of experimental results in terms of formulation by the new model structures and a quality assurance of model formulation.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
B. Breustedt, E. Blanchardon, P. Berard, P. Fritsch, A. Giussani, M. A. Lopez, A. Luciani, D. Nosske, J. Piechowski, J. Schimmelpfeng, et al. BIOKINETIC MODELLING OF DTPA DECORPORATION THERAPY: THE CONRAD APPROACH Radiat Prot Dosimetry, April 7, 2009; (2009) ncp058v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. A. Lopez, G. Etherington, C. M. Castellani, D. Franck, C. Hurtgen, J. W. Marsh, D. Nosske, B. Breustedt, E. Blanchardon, A. Andrasi, et al. INTERNAL DOSIMETRY: TOWARDS HARMONISATION AND COORDINATION OF RESEARCH Radiat Prot Dosimetry, August 30, 2008; (2008) ncn217v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Nosske, A. Birchall, E. Blanchardon, B. Breustedt, A. Giussani, A. Luciani, U. Oeh, and M. A. Lopez DEVELOPMENT, IMPLEMENTATION AND QUALITY ASSURANCE OF BIOKINETIC MODELS WITHIN CONRAD Radiat Prot Dosimetry, August 23, 2008; (2008) ncn219v1. [Abstract] [Full Text] [PDF] |
||||