Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on November 14, 2007
Radiation Protection Dosimetry 2007 127(1-4):343-346; doi:10.1093/rpd/ncm286
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
127/1-4/343    most recent
ncm286v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Birchall, A.
Right arrow Articles by Marsh, J. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Birchall, A.
Right arrow Articles by Marsh, J. W.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2007. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Avoiding biased estimates of dose when nothing is known about the time of intake

A. Birchall*, M. Puncher and J. W. Marsh

Radiation Protection Division, HPA Centre for Radiation, Chemical and Environmental Hazards, Chilton, Didcot, Oxon OX11 0RQ, UK

* Corresponding author: alan.birchall{at}hpa.org.uk

A common problem in internal dosimetry occurs in routine monitoring, when it is required to estimate an intake from a measurement made at the end of a monitoring interval, and the time of intake is unknown. ICRP suggests that it should be assumed that the intake occurred in the middle of the monitoring period. However, it has been shown that this will, in the long-term, lead to biased estimates of a worker's intake and dose. In order to overcome this biasing, the United States Department of Energy (USDOE) recommends a different method based on calculating the intakes for all possible intake times in the interval and then taking an arithmetic average. In a recent paper, it has been shown that both the ICRP and USDOE methods were biased and that the only unbiased estimator of the true intake was obtained by assuming a constant chronic intake throughout the monitoring interval. In all of the analyses carried out to date on this ‘Constant Chronic’ method, it was assumed that the measurements were exact. In this paper, the effects of assuming either normally or log-normally distributed measurement errors are explored, and the effect on the bias of the intake estimate is investigated.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
J. W. Marsh, C. M. Castellani, C. Hurtgen, M. A. Lopez, A. Andrasi, M. R. Bailey, A. Birchall, E. Blanchardon, A. D. Desai, M.-D. Dorrian, et al.
INTERNAL DOSE ASSESSMENTS: UNCERTAINTY STUDIES AND UPDATE OF IDEAS GUIDELINES AND DATABASES WITHIN CONRAD PROJECT
Radiat Prot Dosimetry, October 6, 2008; (2008) ncn218v2.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.