Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on September 28, 2006
Radiation Protection Dosimetry 2007 125(1-4):241-246; doi:10.1093/rpd/ncl133
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
125/1-4/241    most recent
ncl133v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Jones, L. A.
Right arrow Articles by Stokes, R. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jones, L. A.
Right arrow Articles by Stokes, R. P.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Pre-irradiation and post-irradiation fading of the Harshaw 8841 TLD in different environmental conditions

L. A. Jones* and R. P. Stokes

Defence Science and Technology Laboratory Alverstoke, Gosport PO12 2DL, UK

*Corresponding author: Lajones{at}dstl.gov.uk

The pre-irradiation and post-irradiation fading of a commercially available LiF:Mg,Cu,P thermoluminescent detector (TLD)—the Harshaw 8841 TLD—have been assessed. The Harshaw 8841 TLD comprises three TLD-700H chips (99.7% 7LiF and 0.03% 6LiF by weight) and one TLD-600H chip (4.4% 7LiF and 95.6% 6LiF by weight). Pre-irradiation and post-irradiation fading were measured for storage times up to 164 d and three different storage temperatures (–8, 25 and 50°C). Dosemeters were irradiated in a mixed photon–neutron field so that the fading behaviour of the photon and neutron signals could be studied. The TLD-700H and TLD-600H chips exhibited complex changes in sensitivity and signal that depended on storage time, storage temperature and the type of radiation to which the chips had been exposed. However, the magnitudes of these changes in sensitivity and signal were relatively small. TLD-600H and TLD-700H, therefore, exhibit good stability of sensitivity and signal.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.