Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on May 18, 2006
Radiation Protection Dosimetry 2006 119(1-4):191-196; doi:10.1093/rpd/nci557
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
119/1-4/191    most recent
nci557v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Miljanic, S.
Right arrow Articles by Prokic, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Miljanic, S.
Right arrow Articles by Prokic, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2006. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Comparative study of LiF:Mg,Cu,Na,Si and Li2B4O7:Cu,Ag,P TL detectors

S. Miljanic1,*, M. Ranogajec-Komor1, Z. Knezevic1, M. Stuhec2 and M. Prokic3

1 Ruder Boskovic Institute, Bijenicka 54, 10000 Zagreb, Croatia
2 Jozef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia
3 "VINCA" Institute of Nuclear Sciences, 11001 Belgrade, Serbia and Montenegro

* Corresponding author: saveta{at}rudjer.irb.hr

Recently, two new types of ‘tissue equivalent’ thermoluminescent detectors (TLDs) have aroused attention: LiF:Mg,Cu,Na,Si and Li2B4O7:Cu,Ag,P. In this work the characteristics of both detectors were compared with the characteristics of the well-known type LiF:Mg,Ti detector, TLD-100. The following properties were investigated: the glow curve structures, relative sensitivity, batch homogeneity and uniformity, detection threshold, reproducibility of the response, linearity in the wide dose range and fading. Also, the energy dependence for medium and low energy X rays was determined in the range of mean energies between 33 and 116 keV. The results confirmed ‘tissue equivalency’ of both new types in the investigated range of photon energies. LiF:Mg,Cu,Na,Si detector has very high sensitivity (~75 times higher than that of TLD-100) and is convenient for use in a very low range of doses. Li2B4O7:Cu,Ag,P detector shows some improvements in comparison with the previously prepared types of lithium borate. The most important is the five times higher sensitivity than that of TLD-100. This detector is also very promising, especially in medical dosimetry.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.