Skip Navigation


Radiation Protection Dosimetry Advance Access originally published online on August 9, 2005
Radiation Protection Dosimetry 2006 118(1):61-69; doi:10.1093/rpd/nci333
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
118/1/61    most recent
nci333v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Sathyabama, N.
Right arrow Articles by Mayya, Y. S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sathyabama, N.
Right arrow Articles by Mayya, Y. S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2005. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Calibration of an electrostatic chamber for thoron measurements in exhaled breath

N. Sathyabama1, K. P. Eappen2 and Y. S. Mayya2,*

1 Internal Dosimetry Division, Bhabha Atomic Research Centre, Mumbai 400 085, India
2 Environmental Assessment Division Health, Safety and Environment Group, Bhabha Atomic Research Centre, Mumbai 400 085, India

* Corresponding author: mayyays{at}magnum.barc.ernet.in

Received May 5, 2005, amended July 9, 2005, accepted July 9, 2005

An electrostatic chamber system used for measuring thoron in the exhaled breath of thorium workers is calibrated using a standard thoron source and a scintillation cell counting system. A formulation based on both a streamlined flow model and a well-mixed flow model in the chamber has been made to estimate thoron concentration in breath from the observed alpha counts. The experimental measurements of the ratio of the outlet and the inlet thoron concentrations across the chamber strongly validate the well-mixed flow model for thoron, as against the streamlined flow model. The progeny collection efficiency on the electrode has been found to be 70%. The study points out a major error by a factor of ~25 in the calibration factor reported in an earlier work. From the present study, the minimum detectable limit of the activity of 224Ra, freely emanating thoron at mouth works out to be 0.36 Bq as against 0.014 Bq reported earlier for the same system.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.