Radiation Protection Dosimetry Advance Access originally published online on February 3, 2006
Radiation Protection Dosimetry 2005 117(1-3):59-61; doi:10.1093/rpd/nci721
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Patient and staff doses in radiology and cardiology in Estonia
Estonian Radiation Protection Centre, Kopli 76, 10416 Tallinn, Estonia
Corresponding author: irafilippova{at}yahoo.co.in
This paper presents a short description of the Estonian radiological facilities and the doses to staff in radiology and cardiology. For each major work practice, the annual (2002) average effective doses are listed: X-ray diagnostics (radiologists: 1.11 mSv; radiographers: 1.03 mSv), interventional radiology (doctors in cardioangiography: 6.04 mSv; radiologist in angiography: 2.71 mSv), nuclear medicine (radiologists: 0.91 mSv; technicians: 2.41 mSv) and radiotherapy (radiologists: 1.00 mSv; technicians: 1.04 mSv). This paper also presents the first results of adult patient dose measurements in diagnostic X-ray departments in Estonia. The average entrance skin dose for chest PA examinations was 0.3 mGy, for chest LAT 0.9 mGy, for lumbar spine AP 6.4 mGy, for lumbar spine LAT 10.7 mGy and for pelvis AP 3.9 mGy.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
D. Faj, R. Steiner, D. Trifunovic, Z. Faj, M. Kasabasic, D. Kubelka, and Z. Brnic Patient dosimetry in interventional cardiology at the University Hospital of Osijek Radiat Prot Dosimetry, March 1, 2008; 128(4): 485 - 490. [Abstract] [Full Text] [PDF] |
||||