Skip Navigation

Radiation Protection Dosimetry 2005 116(1-4):196-201; doi:10.1093/rpd/nci235
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Hayashi, K.
Right arrow Articles by Kusakabe, K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hayashi, K.
Right arrow Articles by Kusakabe, K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2005. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

Development of a simple method to evaluate medical staff radiation dose and its application to a software system supporting PET facility operation

K. Hayashi1,*, R. Tayama1, K. Shibata1, T. Honda1, M. Morimoto1, T. Izumida1, T. Horikawa2, S. Kanaya2 and K. Kusakabe2

1 Hitachi Ltd, Saiwai-cho 3-1-1, Hitachi, Ibaraki 317-8511, Japan
2 Tokyo Women's Medical University, Kawada-cho 8-1, Shinjuku, Tokyo 162-8666, Japan

* Corresponding author: katsumi-a_hayashi{at}pis.hitachi.co.jp

In recent years, positron-emitting labelled radiopharmaceuticals have come to be used in conjunction with positron emission tomography (PET) in various clinical diagnoses. Radiation exposure of the medical staff is a key issue in the design of PET facilities intended to handle large numbers of persons for PET diagnosis. As a first step, the radiation dose to individuals who received radiopharmaceuticals was calculated using a mathematical phantom model and the EGS4 electromagnetic cascade Monte Carlo code and MCNP Monte Carlo code. Dose rate behind a lead shield was also calculated for various lead thicknesses. The radiation dose distribution around a syringe containing a positron emitter was calculated. The calculated dose distributions were fitted to polynomial equations. These calculations were evaluated against measurements. The second step was to evaluate medical staff dose at a specified time by superimposing dose distribution from each person who received radioisotopes taking into account radioactive decay. In this way, we developed software to support PET facility operation, namely, planning, prediction, control of medical staff dose and facility operation. This system was also designed to schedule daily radiopharmaceuticals production and to manage radioactive wastes by taking decay time into account.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.