Skip Navigation

Radiation Protection Dosimetry 2005 114(1-3):403-405; doi:10.1093/rpd/nch569
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Vassileva, J.
Right arrow Articles by Lichev, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Vassileva, J.
Right arrow Articles by Lichev, A.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2005. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oupjournals.org

Implementation of the European protocol for quality control of the technical aspects of mammography screening in Bulgaria

J. Vassileva1,*, S. Avramova-Cholakova2, A. Dimov1 and A. Lichev3

1 National Centre of Radiobiology and Radiation Protection, 132 Kliment Uhridsky blv., Sofia 1756, Bulgaria
2 Radiological Department, Regional Oncological Hospital, Stara Zagora, Bulgaria
3 Department of Medial Imaging, St Georgi University Hospital, Plovdiv, Bulgaria

* Corresponding author: j.vassileva{at}ncrrp.org

The results from the national pilot project on implementation of the European protocol for the quality control (QC) of the technical aspects of mammography screening as well as the European protocol for dosimetry in mammography in Bulgaria are presented. A QC programme for mammography equipment and a standardised measurement protocol were created. The full QC programme was tested on four mammography units of different types and ages. A national survey was performed for entrance surface air kerma (ESAK) on 20 units using a 45 mm PMMA standard phantom. Average glandular dose (AGD) was calculated using the conversion coefficients from the European dosimetry protocol. The survey demonstrated considerable differences in the technical condition of the mammography units that resulted in varying image quality. The measured values of ESAK showed significant variations. Doses for ~45% of the units were found to be below the European reference level. The values for AGD ranged from 0.35 to 3.47 mGy. The main problems found were film processing, optical density (OD) control settings and AEC adjustment. The results showed the importance of film OD measurements parallel to dose measurements. The X-ray mammography in the country needs optimisation. Comprehensive quality assurance programme should be adopted in all departments covering permanent QC of the equipment, image quality and breast dose.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.