Skip Navigation

Radiation Protection Dosimetry 2005 114(1-3):332-336; doi:10.1093/rpd/nch500
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Bahar Gogani, J.
Right arrow Articles by Wickman, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bahar Gogani, J.
Right arrow Articles by Wickman, G.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2005. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oupjournals.org

Assessment of correlated dose and sensitivity profiles on a multi-slice CT scanner

J. Bahar Gogani1,*, P. Hägglund2 and G. Wickman2

1 Department of Radiation Physics, University Hospital, SE-581 85 Linköping, Sweden
2 Radiation Physics Department, Umeå University, SE-901 85 Umeå, Sweden

* Corresponding author: jalil.bahar{at}lio.se

In the case of computed tomography (CT) scanners as well as other imaging techniques utilising ionising radiation, it is imperative that radiation is confined to the sensitive part of the image detector. Assuring this for a CT scanner requires detailed information about the scanner dose and sensitivity profiles and their spatial correlation. The profiles should ideally be co-centric and tightly fit to each other. Ensuring this inherent performance of the scanner can be seen as one of the fundamental steps in optimising diagnostic examinations with CT. A measurement device using a dedicated liquid ionisation chamber is employed to investigate the performance of a Toshiba Aquilion 16 scanner in this aspect. Dose profile and sensitivity profile pairs for four collimations are presented where each pair of profiles are spatially correlated to each other. The measurement device can be applied to any scanner for fast and accurate assessment of dose and sensitivity profiles and their spatial correlation.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.