Radiation Protection Dosimetry 2005 114(1-3):253-259; doi:10.1093/rpd/nch540
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (3)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Båth, M.
Right arrow Articles by Månsson, L. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Båth, M.
Right arrow Articles by Månsson, L. G.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2005. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oupjournals.org

Method of simulating dose reduction for digital radiographic systems

Magnus Båth1,*, Markus Håkansson1, Anders Tingberg2 and Lars Gunnar Månsson1

1 Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-413 45 Göteborg, Sweden
2 Department of Radiation Physics, Malmö University Hospital, SE-205 02 Malmö, Sweden

* Corresponding author: magnus.bath{at}vgregion.se

The optimisation of image quality vs. radiation dose is an important task in medical imaging. To obtain maximum validity of the optimisation, it must be based on clinical images. Images at different dose levels can then either be obtained by collecting patient images at the different dose levels sought to investigate—including additional exposures and permission from an ethical committee—or by manipulating images to simulate different dose levels. The aim of the present work was to develop a method of simulating dose reduction for digital radiographic systems. The method uses information about the detective quantum efficiency and noise power spectrum at the original and simulated dose levels to create an image containing filtered noise. When added to the original image this results in an image with noise which, in terms of frequency content, agrees with the noise present in an image collected at the simulated dose level. To increase the validity, the method takes local dose variations in the original image into account. The method was tested on a computed radiography system and was shown to produce images with noise behaviour similar to that of images actually collected at the simulated dose levels. The method can, therefore, be used to modify an image collected at one dose level so that it simulates an image of the same object collected at any lower dose level.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
I. A. Tsalafoutas, G. A. Blastaris, A. S. Moutsatsos, P. S. Chios, and E. P. Efstathopoulos
Correlation of image quality with exposure index and processing protocol in a computed radiography system
Radiat Prot Dosimetry, June 1, 2008; 130(2): 162 - 171.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.