Skip Navigation

Radiation Protection Dosimetry 2005 114(1-3):131-134; doi:10.1093/rpd/nch535
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Schuncke, A.
Right arrow Articles by Neitzel, U.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schuncke, A.
Right arrow Articles by Neitzel, U.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2005. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oupjournals.org

Retrospective patient dose analysis of a digital radiography system in routine clinical use

Astrid Schuncke and Ulrich Neitzel*

Philips Medical Systems, Röntgenstrasse 24, D-22335 Hamburg, Germany

* Corresponding author: ulrich.neitzel{at}philips.com

The log files generated in the flat-panel detector based digital radiography systems (Philips Digital Diagnost) at 11 different hospitals were used to acquire data regarding the dose-area product (DAP) and the entrance air kerma (EAK) for all X-ray examinations performed in routine clinical use. A retrospective statistical analysis of the data with respect to the dose levels was performed for several examination types. The resulting average dose levels were compared with the diagnostic reference levels (DRLs). While for the same type of examination the median dose level at different hospitals could differ by up to a factor of 5, almost all the dose levels were found to be much below the published DRL. Only in one hospital for one type of examination (Thorax PA) the DRL for the DAP was slightly exceeded, while for the same site and examination the EAK was still below the DRL. In conclusion, examination log files can be used for retrospective dose analysis and correlation with DRLs.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.