Skip Navigation

Radiation Protection Dosimetry 2005 114(1-3):114-120; doi:10.1093/rpd/nch574
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Håkansson, M.
Right arrow Articles by Månsson, L. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Håkansson, M.
Right arrow Articles by Månsson, L. G.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2005. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oupjournals.org

Nodule detection in digital chest radiography: summary of the RADIUS chest trial

Markus Håkansson1,*, Magnus Båth1, Sara Börjesson1, Susanne Kheddache2, Anna Grahn3, Mark Ruschin3, Anders Tingberg3, Sören Mattsson3 and Lars Gunnar Månsson1

1 Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-413 45 Göteborg, Sweden
2 Department of Radiology, Sahlgrenska University Hospital, SE-413 45 Göteborg, Sweden
3 Department of Medical Radiation Physics, Malmö University Hospital, SE-205 02 Malmö, Sweden

* Corresponding author: markus.hakansson{at}vgregion.se

As a part of the Europe-wide research project ‘Unification of physical and clinical requirements for medical X-ray imaging’—governed by the Radiological Imaging Unification Strategies (RADIUS) Group—a major image quality trial was conducted by members of the group. The RADIUS chest trial aimed at thoroughly examining various aspects of nodule detection in digital chest radiography, such as the effects of nodule location, system noise, anatomical noise, and anatomical background. The main findings of the RADIUS chest trial concerning the detection of a lung nodule with a size in the order of 10 mm can be summarised as: (1) the detectability of the nodule is largely dependent on its location in the chest, (2) the system noise has a minor impact on the detectability at the dose levels used today, (3) the disturbance of the anatomical noise is larger than that of the system noise but smaller than that of the anatomical background and (4) the anatomical background acts as noise to a large extent and is the major image component affecting the detectability of the nodule.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Am. J. Roentgenol.Home page
S. Oda, K. Awai, K. Suzuki, Y. Yanaga, Y. Funama, H. MacMahon, and Y. Yamashita
Performance of Radiologists in Detection of Small Pulmonary Nodules on Chest Radiographs: Effect of Rib Suppression With a Massive-Training Artificial Neural Network
Am. J. Roentgenol., November 1, 2009; 193(5): W397 - W402.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
J. Vikgren, S. Zachrisson, A. Svalkvist, A. A. Johnsson, M. Boijsen, A. Flinck, S. Kheddache, and M. Bath
Comparison of Chest Tomosynthesis and Chest Radiography for Detection of Pulmonary Nodules: Human Observer Study of Clinical Cases
Radiology, December 1, 2008; 249(3): 1034 - 1041.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
L J M Kroft, W J H Veldkamp, B J A Mertens, J-P A van Delft, and J Geleijns
Dose reduction in digital chest radiography and perceived image quality
Br. J. Radiol., December 1, 2007; 80(960): 984 - 988.
[Abstract] [Full Text] [PDF]


Home page
RadiologyHome page
L. J. M. Kroft, W. J. H. Veldkamp, B. J. A. Mertens, J. P. A. van Delft, and J. Geleijns
Detection of simulated nodules on clinical radiographs: dose reduction at digital posteroanterior chest radiography.
Radiology, November 1, 2006; 241(2): 392 - 398.
[Abstract] [Full Text] [PDF]


Home page
The OncologistHome page
M. B. Lobrano
Partnerships in Oncology and Radiology: The Role of Radiology in the Detection, Staging, and Follow-up of Lung Cancer
Oncologist, July 1, 2006; 11(7): 774 - 779.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
S. Borjesson, M. Hakansson, M. Bath, S. Kheddache, S. Svensson, A. Tingberg, A. Grahn, M. Ruschin, B. Hemdal, S. Mattsson, et al.
A software tool for increased efficiency in observer performance studies in radiology
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 45 - 52.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
M. Bath, M. Hakansson, S. Borjesson, S. Kheddache, A. Grahn, M. Ruschin, A. Tingberg, S. Mattsson, and L. G. Mansson
Nodule detection in digital chest radiography: introduction to the RADIUS chest trial
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 85 - 91.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
M. Hakansson, M. Bath, S. Borjesson, S. Kheddache, A. Flinck, G. Ullman, and L. G. Mansson
Nodule detection in digital chest radiography: effect of nodule location
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 92 - 96.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
M. Hakansson, M. Bath, S. Borjesson, S. Kheddache, A. A. Johnsson, and L. G. Mansson
Nodule detection in digital chest radiography: effect of system noise
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 97 - 101.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
M. Bath, M. Hakansson, S. Borjesson, S. Kheddache, A. Grahn, F. O. Bochud, F. R. Verdun, and L. G. Mansson
Nodule detection in digital chest radiography: part of image background acting as pure noise
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 102 - 108.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
M. Bath, M. Hakansson, S. Borjesson, C. Hoeschen, O. Tischenko, S. Kheddache, J. Vikgren, and L. G. Mansson
Nodule detection in digital chest radiography: effect of anatomical noise
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 109 - 113.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
J. Hansson, M. Bath, M. Hakansson, H. Grundin, E. Bjurklint, P. Orvestad, A. Kjellstrom, H. Bostrom, M. Jonsson, K. Jonsson, et al.
An optimisation strategy in a digital environment applied to neonatal chest imaging
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 278 - 285.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
L. G. Mansson, M. Bath, and S. Mattsson
Priorities in optimisation of medical X-ray imaging--a contribution to the debate
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 298 - 302.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.