Nodule detection in digital chest radiography: effect of anatomical noise
1 Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-413 45 Göteborg, Sweden
2 Department of Diagnostic Radiology, Otto-von-Guericke University Hospital, D-391 20 Magdeburg, Germany
3 Departmemt of Radiology, Sahlgrenska University Hospital, SE-413 45 Göteborg, Sweden
* Corresponding author: magnus.bath{at}vgregion.se
The image background resulting from imaged anatomy can be divided into those components that are meaningful to the observers, in the sense that they are recognised as separate structures, and those that are not. These latter components (reffered to as anatomical noise) can be removed using a method developed within the RADIUS group. The aim of the present study was to investigate whether the removal of the anatomical noise results in images where lung nodules with lower contrast can be detected. A receiver operating characteristic (ROC) study was therefore conducted using two types of images: clinical chest images and chest images in which the anatomical noise had been removed. Simulated designer nodules with a full-width-at-fifth-maximum of 10 mm but with varying contrast were added to the images. The contrast needed to obtain an area under the ROC curve of 0.80, C0.8, was used as a measure of detectability (a low value of C0.8 represents a high detectability). Five regions of the chest X ray were investigated and it was found that in all regions the removal of anatomical noise led to images with lower C0.8 than the original images. On average, C0.8 was 20% higher in the original images, ranging from 7% (the lateral pulmonary regions) to 41% (the upper mediastinal regions).
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
J. Vikgren, S. Zachrisson, A. Svalkvist, A. A. Johnsson, M. Boijsen, A. Flinck, S. Kheddache, and M. Bath Comparison of Chest Tomosynthesis and Chest Radiography for Detection of Pulmonary Nodules: Human Observer Study of Clinical Cases Radiology, December 1, 2008; 249(3): 1034 - 1041. [Abstract] [Full Text] [PDF] |
||||
![]() |
D S Brettle, E Berry, and M A Smith The effect of experience on detectability in local area anatomical noise Br. J. Radiol., March 1, 2007; 80(951): 186 - 193. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Borjesson, M. Hakansson, M. Bath, S. Kheddache, S. Svensson, A. Tingberg, A. Grahn, M. Ruschin, B. Hemdal, S. Mattsson, et al. A software tool for increased efficiency in observer performance studies in radiology Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 45 - 52. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Bath, M. Hakansson, S. Borjesson, S. Kheddache, A. Grahn, M. Ruschin, A. Tingberg, S. Mattsson, and L. G. Mansson Nodule detection in digital chest radiography: introduction to the RADIUS chest trial Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 85 - 91. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Hakansson, M. Bath, S. Borjesson, S. Kheddache, A. Flinck, G. Ullman, and L. G. Mansson Nodule detection in digital chest radiography: effect of nodule location Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 92 - 96. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Hakansson, M. Bath, S. Borjesson, S. Kheddache, A. A. Johnsson, and L. G. Mansson Nodule detection in digital chest radiography: effect of system noise Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 97 - 101. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Bath, M. Hakansson, S. Borjesson, S. Kheddache, A. Grahn, F. O. Bochud, F. R. Verdun, and L. G. Mansson Nodule detection in digital chest radiography: part of image background acting as pure noise Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 102 - 108. [Abstract] [Full Text] [PDF] |
||||