Skip Navigation

Radiation Protection Dosimetry 2005 114(1-3):109-113; doi:10.1093/rpd/nch526
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (10)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Båth, M.
Right arrow Articles by Månsson, L. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Båth, M.
Right arrow Articles by Månsson, L. G.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2005. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oupjournals.org

Nodule detection in digital chest radiography: effect of anatomical noise

Magnus Båth1,*, Markus Håkansson1, Sara Börjesson1, Christoph Hoeschen2, Oleg Tischenko2, Susanne Kheddache3, Jenny Vikgren3 and Lars Gunnar Månsson1

1 Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, SE-413 45 Göteborg, Sweden
2 Department of Diagnostic Radiology, Otto-von-Guericke University Hospital, D-391 20 Magdeburg, Germany
3 Departmemt of Radiology, Sahlgrenska University Hospital, SE-413 45 Göteborg, Sweden

* Corresponding author: magnus.bath{at}vgregion.se

The image background resulting from imaged anatomy can be divided into those components that are meaningful to the observers, in the sense that they are recognised as separate structures, and those that are not. These latter components (reffered to as anatomical noise) can be removed using a method developed within the RADIUS group. The aim of the present study was to investigate whether the removal of the anatomical noise results in images where lung nodules with lower contrast can be detected. A receiver operating characteristic (ROC) study was therefore conducted using two types of images: clinical chest images and chest images in which the anatomical noise had been removed. Simulated designer nodules with a full-width-at-fifth-maximum of 10 mm but with varying contrast were added to the images. The contrast needed to obtain an area under the ROC curve of 0.80, C0.8, was used as a measure of detectability (a low value of C0.8 represents a high detectability). Five regions of the chest X ray were investigated and it was found that in all regions the removal of anatomical noise led to images with lower C0.8 than the original images. On average, C0.8 was 20% higher in the original images, ranging from 7% (the lateral pulmonary regions) to 41% (the upper mediastinal regions).


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
J. Vikgren, S. Zachrisson, A. Svalkvist, A. A. Johnsson, M. Boijsen, A. Flinck, S. Kheddache, and M. Bath
Comparison of Chest Tomosynthesis and Chest Radiography for Detection of Pulmonary Nodules: Human Observer Study of Clinical Cases
Radiology, December 1, 2008; 249(3): 1034 - 1041.
[Abstract] [Full Text] [PDF]


Home page
Br. J. Radiol.Home page
D S Brettle, E Berry, and M A Smith
The effect of experience on detectability in local area anatomical noise
Br. J. Radiol., March 1, 2007; 80(951): 186 - 193.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
S. Borjesson, M. Hakansson, M. Bath, S. Kheddache, S. Svensson, A. Tingberg, A. Grahn, M. Ruschin, B. Hemdal, S. Mattsson, et al.
A software tool for increased efficiency in observer performance studies in radiology
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 45 - 52.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
M. Bath, M. Hakansson, S. Borjesson, S. Kheddache, A. Grahn, M. Ruschin, A. Tingberg, S. Mattsson, and L. G. Mansson
Nodule detection in digital chest radiography: introduction to the RADIUS chest trial
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 85 - 91.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
M. Hakansson, M. Bath, S. Borjesson, S. Kheddache, A. Flinck, G. Ullman, and L. G. Mansson
Nodule detection in digital chest radiography: effect of nodule location
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 92 - 96.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
M. Hakansson, M. Bath, S. Borjesson, S. Kheddache, A. A. Johnsson, and L. G. Mansson
Nodule detection in digital chest radiography: effect of system noise
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 97 - 101.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
M. Bath, M. Hakansson, S. Borjesson, S. Kheddache, A. Grahn, F. O. Bochud, F. R. Verdun, and L. G. Mansson
Nodule detection in digital chest radiography: part of image background acting as pure noise
Radiat Prot Dosimetry, May 17, 2005; 114(1-3): 102 - 108.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.