Radiation Protection Dosimetry 106:241-246 (2003)
© 2003 Oxford University Press

Radiation doses to patients from endoscopic retrograde cholangiopancreatography examinations and image quality considerations

I. A. Tsalafoutas, K. D. Paraskeva, E. N. Yakoumakis, A. E. Vassilaki, P. N. Maniatis, J. A. Karagiannis and E. D. Koulentianos

The purpose of this investigation was to measure the dose-area product (DAP) and the other relevant dosimetric quantities in diagnostic and therapeutic endoscopic retrograde cholangiopancreatography (ERCP). Furthermore, the dependence of patient dose and image quality on the tube potential was investigated. A DAP meter was used for dose monitoring in seven diagnostic and 21 therapeutic ERCPs. For each ERCP the DAP meter readings, fluoroscopy time, number of radiographs and exposure data were recorded. From these data the fluoroscopy and radiography contributions to DAP, the entrance skin dose and the effective dose for each examination were estimated. For the investigation of the effect of tube potential on patient dose and image quality, a water phantom containing syringes filled with diluted contrast media was used. The average DAP was 13.7 Gy cm2 in diagnostic and 41.8 Gy cm2 in therapeutic ERCP whereas the average fluoroscopy times were 3.1 and 6.0 min respectively. DAP was strongly correlated to the fluoroscopy time. Measurements in the phantom showed that a good compromise between image quality and patient dose is obtained for tube potentials around 80 kV. Therapeutic ERCPs deliver on average higher doses to patients than diagnostic ERCPs. However, for a difficult diagnostic ERCP more patient exposure may be required than for a simple therapeutic ERCP.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer:
Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.