Skip Navigation



Radiation Protection Dosimetry Advance Access published online on October 28, 2009

Radiation Protection Dosimetry, doi:10.1093/rpd/ncp236
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Choi, J.
Right arrow Articles by Cho, P.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Choi, J.
Right arrow Articles by Cho, P.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2009. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

THE DEVELOPMENT OF A GUIDANCE LEVEL FOR PATIENT DOSE FOR CT EXAMINATIONS IN KOREA

JongHak Choi1, SangHoon Cha2, KiYeol Lee2, DongChul Shin2, JungHo Kang1, YouHyun Kim1, KiHyun Kim3 and PyongKon Cho2,*

1 Department of Radiologic Science, College of Health Science, Korea University, Seoul, Korea
2 Department of Diagnostic Radiology, Ansan Hospital, Korea University Medical Center, Ansan 425-707, Korea
3 Brookhaven National Laboratory, Upton, NY 11973, USA

* Corresponding author: jjjpkcho{at}korea.ac.kr

Received April 17, 2009, amended September 16, 2009, accepted September 23, 2009

The primary goal of this study was to analyse the state of patient doses in the field of computed tomography (CT) examinations in the Republic of Korea. All survey data including the CT applications and patient dose details were obtained from general hospitals registered in the Korean Hospital Association. The systematic analysis of the patient dose survey gives target values of the weighted computed tomography dose index (CTDIw) and the dose–length product (DLP). The targeted CTDIw values were 69, 69, 31, 19, 44, 25, 24, 20, 2, 19 and 19 mGy for the brain non-contrast enhancement (BNCE), brain contrast enhancement (BCE), neck, chest, spine, liver, pancreas, stomach, kidneys, abdomen routine and abdomen trauma protocols, respectively. The targeted DLP values were 1056, 2112, 762, 1234, 1338, 2794, 2742, 2378, 2836, 1844 and 1939 mGy cm for the BNCE, BCE, neck, chest, spine, liver, pancreas, stomach, kidneys, abdomen routine and abdomen trauma protocols, respectively. Comparing with the EUR recommendation, especially in the DLP, the adjustment of the total scan phase frequency and the shortening of the scan phase in each scan phase are needed to reduce the patients radiation exposure to international standards.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.