Skip Navigation



Radiation Protection Dosimetry Advance Access published online on October 21, 2009

Radiation Protection Dosimetry, doi:10.1093/rpd/ncp222
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Catarinucci, L.
Right arrow Articles by Tarricone, L.
PubMed
Right arrow PubMed Citation
Right arrow Articles by Catarinucci, L.
Right arrow Articles by Tarricone, L.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2009. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

ON THE USE OF ADVANCED NUMERICAL MODELS FOR THE EVALUATION OF DOSIMETRIC PARAMETERS AND THE VERIFICATION OF EXPOSURE LIMITS AT WORKPLACE

L. Catarinucci* and L. Tarricone

Innovation Engineering Department, University of Salento, via per Monteroni, 73100 Lecce, Italy

* Corresponding author: luca.catarinucci{at}unisalento.it

With the next transposition of the 2004/40/EC Directive, employers will become responsible for the electromagnetic field level at the workplace. To make this task easier, the scientific community is compiling practical guidelines to be followed. This work aims at enriching such guidelines, especially for the dosimetric issues. More specifically, some critical aspects related to the application of numerical dosimetric techniques for the verification of the safety limit compliance have been highlighted. In particular, three different aspects have been considered: the dosimetric parameter dependence on the shape and the inner characterisation of the exposed subject as well as on the numerical algorithm used, and the correlation between reference limits and basic restriction. Results and discussions demonstrate how, even by using sophisticated numerical techniques, in some cases a complex interpretation of the result is mandatory.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.