Skip Navigation



Radiation Protection Dosimetry Advance Access published online on February 16, 2009

Radiation Protection Dosimetry, doi:10.1093/rpd/ncp007
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
133/1/25    most recent
ncp007v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Hambali, A. S.
Right arrow Articles by Suleiman, O. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hambali, A. S.
Right arrow Articles by Suleiman, O. H.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2009. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

ENTRANCE SURFACE DOSE AND IMAGE QUALITY: COMPARISON OF ADULT CHEST AND ABDOMINAL X-RAY EXAMINATIONS IN GENERAL PRACTITIONER CLINICS, PUBLIC AND PRIVATE HOSPITALS IN MALAYSIA

Ahmad Shariff Hambali1, Kwan-Hoong Ng2,*, Basri Johan Jeet Abdullah2, Hwee-Beng Wang1, Noriah Jamal3, David C. Spelic4 and Orhan H. Suleiman4

1 Engineering Services Division, Ministry of Health Malaysia, Level 2–5, Block E6, Parcel 1, Federal Government Administration Centre, 62590 Putrajaya, Malaysia
2 Department of Biomedical Imaging, University of Malaya, 50603 Kuala Lumpur, Malaysia
3 Medical Technology Division, Malaysian Nuclear Agency, 43000 Kajang, Malaysia
4 Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Avenue, Silver Spring, MD 20903, USA

* Corresponding author: ngkh{at}um.edu.my; dwlng{at}tm.net.my

Received June 2, 2008, amended December 23, 2008, accepted January 18, 2009

This study was undertaken to compare the entrance surface dose (ESD) and image quality of adult chest and abdominal X-ray examinations conducted at general practitioner (GP) clinics, and public and private hospitals in Malaysia. The surveyed facilities were randomly selected within a given category (28 GP clinics, 20 public hospitals and 15 private hospitals). Only departmental X-ray units were involved in the survey. Chest examinations were done at all facilities, while only hospitals performed abdominal examinations. This study used the x-ray attenuation phantoms and protocols developed for the Nationwide Evaluation of X-ray Trends (NEXT) survey program in the United States. The ESD was calculated from measurements of exposure and clinical geometry. An image quality test tool was used to evaluate the low-contrast detectability and high-contrast detail performance under typical clinical conditions. The median ESD value for the adult chest X-ray examination was the highest (0.25 mGy) at GP clinics, followed by private hospitals (0.22 mGy) and public hospitals (0.17 mGy). The median ESD for the adult abdominal X-ray examination at public hospitals (3.35 mGy) was higher than that for private hospitals (2.81 mGy). Results of image quality assessment for the chest X-ray examination show that all facility types have a similar median spatial resolution and low-contrast detectability. For the abdominal X-ray examination, public hospitals have a similar median spatial resolution but larger low-contrast detectability compared with private hospitals. The results of this survey clearly show that there is room for further improvement in performing chest and abdominal X-ray examinations in Malaysia.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.