Skip Navigation



Radiation Protection Dosimetry Advance Access published online on December 23, 2008

Radiation Protection Dosimetry, doi:10.1093/rpd/ncn310
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
132/4/375    most recent
ncn310v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Mesbahi, A.
Right arrow Articles by Aslanabadi, N.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mesbahi, A.
Right arrow Articles by Aslanabadi, N.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2008. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

A STUDY ON PATIENTS' RADIATION DOSES FROM INTERVENTIONAL CARDIAC PROCEDURES IN TABRIZ, IRAN

Asghar Mesbahi1,2,* and Naser Aslanabadi3

1 Medical Physics Department, Medical School, Tabriz University of Medical Sciences, Iran
2 Radiation Oncology Department, Imam Khomeini Hospital, Tabriz, Iran
3 Cardiology Department, Medical School, Tabriz University of Medical Sciences, Iran

* Corresponding author: asgharmesbahi{at}yahoo.com

Received August 19, 2008, amended November 24, 2008, accepted December 3, 2008

Interventional cardiac procedures produce a large amount of X-ray exposures to the patients in comparison with other conventional X-ray imaging procedures. In the current study, the exposure parameters of 580 patients referred to a cardiac angiography department were recorded. The mean values of total kerma–area product (KAP) were 18.6 Gy cm2 for coronary angiography (CA) and 55 Gy cm2 for percutaneous transluminal coronary angioplasty (PTCA). The mean fluoroscopy time was 3.2 and 11.6 min, respectively, for CA and PTCA. The patients' exposure parameters during electrophysiological studies were 15.5 min for mean fluoroscopy time and 33.9 Gy cm2 for total KAP. For paediatrics, the mean fluoroscopy time of 5.4 min and total KAP of 2 Gy cm2 were recorded. Comparing the proposed reference values, the authors think that the exposure level of patients in their department is at an acceptable level.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.