Skip Navigation


Radiation Protection Dosimetry Advance Access first published online on August 21, 2008
This version published online on October 6, 2008

Radiation Protection Dosimetry, doi:10.1093/rpd/ncn218
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
131/1/34    most recent
ncn218v2
ncn218v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Marsh, J. W.
Right arrow Articles by Vrba, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Marsh, J. W.
Right arrow Articles by Vrba, T.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© The Author 2008. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oxfordjournals.org

INTERNAL DOSE ASSESSMENTS: UNCERTAINTY STUDIES AND UPDATE OF IDEAS GUIDELINES AND DATABASES WITHIN CONRAD PROJECT

J. W. Marsh1,*, C. M. Castellani2, C. Hurtgen3, M. A. Lopez4, A. Andrasi5, M. R. Bailey1, A. Birchall1, E. Blanchardon6, A. D. Desai1, M.-D. Dorrian1, H. Doerfel7, V. Koukouliou8, A. Luciani2, I. Malatova9, A. Molokanov6, M. Puncher1 and T. Vrba9

1 Health Protection Agency, Radiation Protection Division, Chilton, Didcot, UK
2 ENEA, Radiation Protection Institute, Bologna, Italy
3 SCK CEN, Belgian Nuclear Research Centre, Mol, Belgium
4 CIEMAT, Centro de Investigaciones Energéticas Medioambientales y Tecnologicas, Avda Complutense 22, 28040 Madrid, Spain
5 KFKI, Atomic Energy Research Institute, Budapest, Hungary
6 Institut de Radioprotection et de Sûreté Nucléaire, Fontenay-aux-Roses, France
7 Forschungszentrum Karlsruhe GmbH, Karlsruhe, Germany
8 GAEC, Greek Atomic Energy Commission, Athens, Greece
9 National Radiation Protection Institute, Praha, Czech Republic

* Corresponding author: james.marsh{at}hpa.org.uk

The work of Task Group 5.1 (uncertainty studies and revision of IDEAS guidelines) and Task Group 5.5 (update of IDEAS databases) of the CONRAD project is described. Scattering factor (SF) values (i.e. measurement uncertainties) have been calculated for different radionuclides and types of monitoring data using real data contained in the IDEAS Internal Contamination Database. Based upon this work and other published values, default SF values are suggested. Uncertainty studies have been carried out using both a Bayesian approach as well as a frequentist (classical) approach. The IDEAS guidelines have been revised in areas relating to the evaluation of an effective AMAD, guidance is given on evaluating wound cases with the NCRP wound model and suggestions made on the number and type of measurements required for dose assessment.


‘A sentence beginning "For example, Vrba (2007) ... " has been removed from the end of the first column on page 2’


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
G. H. Kramer
Canadian national internal dosimetry performance testing programme: results of the pilot programme
Radiat Prot Dosimetry, June 1, 2009; 134(2): 107 - 112.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.