Skip Navigation


Radiation Protection Dosimetry Advance Access first published online on April 16, 2008
This version published online on September 18, 2008

Radiation Protection Dosimetry, doi:10.1093/rpd/ncn133
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow All Versions of this Article:
131/2/229    most recent
ncn133v2
ncn133v1
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by McCaffrey, J. P.
Right arrow Articles by Downton, B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McCaffrey, J. P.
Right arrow Articles by Downton, B.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

© 2008 National Research Council of Canada and Canadian Crown Copyright

DOSE RATE DEPENDENCY OF ELECTRONIC PERSONAL DOSEMETERS MEASURING X- AND {gamma}-RAY RADIATION

J. P. McCaffrey*, H. Shen and B. Downton

Institute for National Measurement Standards, National Research Council of Canada, 1200 Montreal Road, M-35, Ottawa, K1A 0R6 Canada

* Corresponding author: john.mccaffrey{at}nrc-cnrc.gc.ca

Received January 30, 2008, amended March 12, 2008, accepted March 13, 2008

Three models of electronic personal dosemeters (EPDs)—Siemens Mk 2.3, Rados RAD-60S and Vertec Bleeper Sv—were irradiated with seven photon beam qualities: 60Co, 137Cs and the ISO narrow spectrum series X-ray qualities N-250, N-200, N-150, N-60 and N-20. The personal dose equivalent rates delivered to the devices varied between 0.002 and 0.25 mSv s–1. Measurements were made with the EPDs mounted free-in-air as well as against Lucite and water phantoms. Results for all models of EPDs showed differences in personal dose equivalent energy response for different energies covered by this range of radiation qualities, with different models showing variations from 15 to 65%. In some cases, the personal dose equivalent rate response of these devices varied by a factor of 3 between irradiations at typical calibration dose rates and those normally encountered by nuclear energy workers.


This version changes the last radiation quality in Table 1 from 6 to 60Co


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.