Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (16)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Schrewe, U.J.
Right arrow Articles by Silari, M.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Schrewe, U.J.
Right arrow Articles by Silari, M.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Radiation Protection Dosimetry 86:289-295 (1999)
© 1999 Oxford University Press

Calibration Problems, Calibration Procedures and Reference Fields for Dosimetry at Flight Altitudes

U.J. Schrewe, W.G. Alberts, A.V. Alevra, A. Ferrari, T. Otto and M. Silari

Dosemeters used to measure the ambient dose equivalent, H*(10), usually require calibration with respect to this quantity. Under calibration conditions, the calibrated instrument will then measure H*(10) correctly, but under different irradiation conditions with respect to field composition, particle energies or other influencing quantities, deviations will most probably occur since the instruments in use do not have ideal response characteristics. The accuracy in aircrew exposure monitoring will be improved by performing the calibration in the field of interest itself or in a calibration field which has similar characteristics. Direct calibration requires a reference instrument that should be able to measure H*(10) correctly for all radiation components and energies in the field of interest. The use of reference fields produced under laboratory conditions requires similar particle composition and similar energy distributions of fluence. It is demonstrated that for radiation exposure monitoring in aircraft the tissue-equivalent proportional counter (TEPC) can, to a fair approximation, be a reference instrument for H*(10) and that the reference field facility installed at the proton synchrotron accelerator at CERN can provide reference fields of close similarity.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
R. Machrafi, K. Garrow, H. Ing, M. B. Smith, H. R. Andrews, Yu. Akatov, V. Arkhangelsky, I. Chernykh, V. Mitrikas, V. Petrov, et al.
NEUTRON DOSE STUDY WITH BUBBLE DETECTORS ABOARD THE INTERNATIONAL SPACE STATION AS PART OF THE MATROSHKA-R EXPERIMENT
Radiat Prot Dosimetry, March 23, 2009; (2009) ncp039v1.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
S. Mayer, D. Forkel-Wirth, M. Fuerstner, H. G. Menzel, M. J. Mueller, D. Perrin, C. Theis, and H. Vincke
Response of neutron detectors to high-energy mixed radiation fields
Radiat Prot Dosimetry, July 1, 2007; 125(1-4): 289 - 292.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
F. Wissmann
Long-term measurements of H*(10) at aviation altitudes in the northern hemisphere
Radiat Prot Dosimetry, December 1, 2006; 121(4): 347 - 357.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
S. Mayer, N. Golnik, J. E. Kyllonen, H. G. Menzel, and Th. Otto
Dose equivalent measurements in a strongly pulsed high-energy radiation field
Radiat Prot Dosimetry, August 1, 2004; 110(1-4): 759 - 762.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
J. C. McDonald
Calibration measurements and standards for radiation protection dosimetry
Radiat Prot Dosimetry, July 1, 2004; 109(4): 317 - 321.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.