Skip Navigation

This Article
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrow Search for citing articles in:
ISI Web of Science (5)
Right arrowRequest Permissions
Google Scholar
Right arrow Articles by Fantuzzi, E.
Right arrow Articles by Vilela, E.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Fantuzzi, E.
Right arrow Articles by Vilela, E.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Radiation Protection Dosimetry 85:85-89 (1999)
© 1999 Oxford University Press

A TL Dosemeter for Mixed Thermal Neutron and Gamma Fields Based on GR-200 and GR-207 Detectors

E. Fantuzzi, G.F. Gualdrini, F. Monteventi, B. Morelli and E. Vilela

A new ENEA dosemeter based on two TL detectors, LiF(Mg,Cu,P) (GR-200) and 7LiF(Mg,Cu,P) (GR-207), was investigated. The different thermal neutron and gamma sensitivities of the two detectors allow a good dose equivalent estimation in mixed n-? fields. The higher sensitivity of both detectors as compared with LiF(Mg,Ti) and 7LiF(Mg,Ti) detectors, currently used at ENEA for routine personal dosimetry, allows a lower dose equivalent threshold to be achieved as well as a better discrimination of the neutron and gamma components of the radiation field. A dose calculation algorithm was developed and assessed by experimental tests performed both at ENEA Institute for Radiation Protection thermal neutron irradiation facility as well as at the IPSN SIGMA facility in Cadarache (France). The intercalibration test supplied the necessary guidelines for future routine dosemeter calibrations. Our results demonstrated that the new dosemeter can easily replace the currently employed dosemeter for mixed thermal neutron and gamma fields in routine personal dosimetry.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Radiat Prot DosimetryHome page
R. Bedogni, A. Esposito, M. Chiti, and M. Angelone
Neutron spectrometry around a high-energy electron-positron collider using a multi-sphere system with passive detectors
Radiat Prot Dosimetry, August 1, 2007; 126(1-4): 541 - 545.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
B. Morelli, F. Mariotti, and E. Fantuzzi
The ENEA neutron personal dosimetry service
Radiat Prot Dosimetry, September 1, 2006; 120(1-4): 312 - 315.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
G. Gualdrini, R. Bedogni, and F. Monteventi
Developing a thermal neutron irradiation system for the calibration of personal dosemeters in terms of HP(10)
Radiat Prot Dosimetry, August 1, 2004; 110(1-4): 43 - 48.
[Abstract] [Full Text] [PDF]


Home page
Radiat Prot DosimetryHome page
G. Gualdrini, R. Bedogni, E. Fantuzzi, and F. Mariotti
The ENEA criticality accident dosimetry system: a contribution to the 2002 international intercomparison at the SILENE reactor
Radiat Prot Dosimetry, August 1, 2004; 110(1-4): 465 - 469.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.