Radiation Protection Dosimetry 85:49-56 (1999)
© 1999 Oxford University Press
Personnel Dosimetry Using LiF:Mg,Cu,P
Significant advances have been made in recent years in the development of new and improved thermoluminescent (TL) materials for applications in personnel and environmental dosimetry. One of the most promising new TL materials is LiF:Mg,Cu,P. This paper provides an up-to-date review of the main dosimetric properties of LiF:Mg,Cu,P, emphasising recent improvements in the preparation of this material. An attempt is made to focus on the TL characteristics that are particularly useful for personnel monitoring, although most are relevant to environmental dosimetry as well. Advantages of LiF:Mg,Cu,P include high sensitivity as compared to LiF:Mg,Ti, almost flat photon energy response, low fading rate and linear dose response. The lack of supralinearity at higher dose levels is particularly useful for accident dosimetry, and eliminates the source of error usually associated with the application of supralinearity corrections. The main drawbacks are still the relatively high residual signal and the loss of sensitivity for high readout temperatures. This does not limit the usefulness of LiF:Mg,Cu,P for low dose levels typical to personnel or environmental dosimetry, but may be a limiting factor for high dose applications such as clinical dosimetry.
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
E. Brunckhorst, X. Sheng, M. Todorovic, J. Becker, and F. Cremers CHARACTERISATION OF MCP-600D AND MCP-700D THERMOLUMINESCENCE DETECTORS AND THEIR APPLICABILITY FOR PHOTONEUTRON DETECTION Radiat Prot Dosimetry, October 15, 2008; (2008) ncn251v1. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Delzer, J. R. Hawley, A. Romanyukha, S. Nemmers, R. Selwyn, and L. A. Benevides Long-term fade study of the DT-702 LiF: Mg,Cu,P TLD Radiat Prot Dosimetry, September 1, 2008; 131(3): 279 - 286. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. J. Gilvin, S. T. Baker, T. J. Daniels, J. D. Eakins, D. R. McClure, D. T. Bartlett, and C. Boucher Type testing of a new TLD for the UK Health Protection Agency Radiat Prot Dosimetry, January 1, 2008; 128(1): 36 - 42. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. T. Baker and P. J. Gilvin Comparison of the effects of exposure to light in Harshaw LiF:Mg,Ti and LiF:Mg,Cu,P Radiat Prot Dosimetry, July 1, 2007; 125(1-4): 258 - 260. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. J. Gilvin, L. Z. Luo, S. T. Baker, C. E. Hill, and J. E. Rotunda Type testing of an extremity finger stall dosemeter based on Harshaw TLD EXTRADTM technology Radiat Prot Dosimetry, February 1, 2007; 123(3): 329 - 336. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. J. Velbeck, L. Z. Luo, M. J. Ramlo, and J. E. Rotunda The dose-response of Harshaw TLD-700H Radiat Prot Dosimetry, September 1, 2006; 119(1-4): 255 - 258. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Z. Luo, K. J. Velbeck, M. Moscovitch, and J. E. Rotunda LiF:Mg,Cu,P glow curve shape dependence on heating rate Radiat Prot Dosimetry, September 1, 2006; 119(1-4): 184 - 190. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Z. Luo and J. E. Rotunda Performance of Harshaw TLD-100H two-element Dosemeter Radiat Prot Dosimetry, September 1, 2006; 120(1-4): 324 - 330. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. J. St John, J. R. Cassata, P. K. Blake, W. H. Wallace, and R. Minniti Technical aspects of the Naval Dosimetry Center quality assurance programme Radiat Prot Dosimetry, September 1, 2006; 120(1-4): 273 - 277. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Moscovitch, T. J. St. John, J. R. Cassata, P. K. Blake, J. E. Rotunda, M. Ramlo, K. J. Velbeck, and L. Z. Luo The application of LiF:Mg,Cu,P to large scale personnel dosimetry: current status and future directions Radiat Prot Dosimetry, September 1, 2006; 119(1-4): 248 - 254. [Abstract] [Full Text] [PDF] |
||||